Figure 38 Output Configuration
6.4
Using Outputs
Outputs 0-5 can be controlled with M-Codes. One M-Code turns an output on, and the other M-Code turns the output
off. Use the table below for a reference.
Custom M-Codes
M200
M201
M202
M203
M204
M205
M206
M207
M208
M209
M210
M211
Table 7 M-Codes for Outputs
6.5
Mist and Flood Control
Mist is already preconfigured in the software to be wired into Y0 and flood into Y1output terminals.
Feature
Mist
Flood
Table 8 Mist and Flood Control
7 Advanced Options and Information
7.1 MachMotion Plugin
A number of advanced features can be accessed and configured in the MachMotion plugin such as periodic oiler
control and custom user messages (Global Messaging). Begin by going to Configure->Plugins to open the
MachMotion plugin.
Functions
Output 0 on
Output 0 off
Output 1 on
Output 1 off
Output 2 on
Output 2 off
Output 3 on
Output 3 off
Output 4 on
Output 4 off
Output 5 on
Output 5 off
ON M-Code
M7
M8
OFF M-Code
M9
Default Output
Y2
Y3
Y4
Y5
Y6
Y7
Preconfigured Output
Mist On – [P11 Output0]
Coolant On – [P11 Output1]