The outputs and associated LEDs are labeled Y0 through Y7. If the LED is on, the output is activated.
6.2
Wiring Outputs
There are two separate commons for the outputs. The common C1+ is for outputs Y0-Y3 and C2+ is for Y4-Y7. Each
common can take 7-48VDC. If the outputs being used are using the voltage supply from Apollo III, each output can only
supply 125mA. However, if they are supplied using a separate voltage source, each output can source up to 250mA.
For standard operation the output commons are jumpered to 24V on the Apollo III. At that point simply connect the
load between the output and GND. See the figure below.
6.3
Configuring Outputs
To configure an output, follow the procedure below.
1. On the menu bar click on Config->Control.
2. Select the Output Signals
3. Scroll down to the desired output (There are 64 output signals available).
4. Enable the output by setting the Mapping Enabled box to a green check.
5. Set the Device to HiCON and the Output Name to [P11] and the corresponding Y number (Y3 would be
Output3).
6. Set the Active Low column to a green check for a normally closed signal or red x for normally open.
7. Press [OK] to save changes.
Figure 36 Outputs
Figure 37 Standard 24V 125mA Outputs