Adaptec 2025ZCR Installation And User Manual page 140

Sata and scsi raid controller
Hide thumbs Also See for 2025ZCR:
Table of Contents

Advertisement

Parameters
{enclosure}—ID number of the enclosure management device
on which to prepare a slot.
{slot}—Unit number of the slot.
enclosure set alarm [/on={boolean}] {enclosure}
Turns the audible alarm on or off.
Parameters
{enclosure}—ID number of the enclosure management device
whose audible alarm to set.
Switches
/on—Specifies whether to turn the audible alarm on or off.
enclosure set fan [/off={boolean}] {enclosure} {fan} [{speed}]
Sets the speed of a specific fan.
Parameters
{enclosure}—ID number of the enclosure management device
on which to set the speed of a fan.
{fan}—Unit number of the fan.
{speed}—Speed at which to set the fan.
Switches
/off—Specifies whether to turn off the fan.
enclosure set interval {second}
Sets the monitor reporting interval (in seconds).
Parameters
{second}—Number of seconds for the monitor reporting
interval.
enclosure set power [/off{=boolean}] {enclosure}
{powersupply}
Turns on or off a specific power supply.
Command Line Interface
D-35

Advertisement

Table of Contents
loading