When Adding a magnetometer into the system, the startup.ini file must be modified
by adding the line set DEFAULTUPLINK 1. The new startup.ini file will look like this:
set SONARTYPE 3000
set RANGE 2
set RESPDIV 15
set RESPFREQ 7
set DESPECKLESWITCH 0
set SPEEDFILTERSWITCH 1
set TVGPAGE 7
set SPEEDSOUND 150000
set BAUDRATE 4800
set STANDBYMODE 0
set DEFAULTUPLINK 1
set TOWFISHECHO 0
set DIAGLEVEL 1
If you switch back to not using a magnetometer, you can simply set the DEFAULTU-
PLINK to 0. The startup.ini file will now look like this:
set SONARTYPE 3000
set RANGE 2
set RESPDIV 15
set RESPFREQ 7
set DESPECKLESWITCH 0
set SPEEDFILTERSWITCH 1
set TVGPAGE 7
set SPEEDSOUND 150000
set BAUDRATE 4800
set STANDBYMODE 0
set DEFAULTUPLINK 0
set TOWFISHECHO 0
set DIAGLEVEL 1
Don't forget to save the changed startup.ini file.