SYSTEM 3000 OPERATIONS AND MAINTENANCE MANUAL
INFORMATION FOR SYSTEM 3000 OPERATIONS
The System 3000 is designed for easy operation with most popular magnetometers.
Configuring the System 3000 for use with the magnetometer.
Magnetometer power voltage is set on the Multiplexer board with a jumper on JP2.
Select the appropriate voltage from one of the following positions.
1-2 external power (default when no magnetometer is in use)
3-4 +5 volts
5-6 +12 volts
7-8 +200 volts
The Klein startup.ini file located in the klein folder is used to set boot parameters.
The following is a typical .ini file:
set SONARTYPE 3000
set RANGE 2
set RESPDIV 15
set RESPFREQ 7
set DESPECKLESWITCH 0
set SPEEDFILTERSWITCH 1
set TVGPAGE 7
set SPEEDSOUND 150000
set BAUDRATE 4800
set STANDBYMODE 0
set DIAGLEVEL 1
L-3 Klein Associates, Inc.
APPENDIX C
WITH A MAGNETOMETER