SYSTEM 3000 OPERATIONS AND MAINTENANCE MANUAL
4.32

COMPASS CALIBRATION.

A compass calibration wizard was added to SonarPro, with the release of version 5.2.
To use, Select:
Sonar Interface
Towfish Diagnostics
Run Compass Calibration Wizard
Follow the instructions and play the demonstration animation.
This must be done away from all magnetic and metal sources, and in most cases, it
will have to be done off the ship.
First, enable the towfish compass calibration mode; then rotate the towfish slowly 360
degrees in a circle (for more than a minute). At the same time you must pitch and roll
the towfish beyond its 20 degree limits, we suggest 45 degrees to be safe.
Excellent calibration results have been obtained by enabling the
compass calibration and towing the towfish in a series of three cir-
cles with the boat.
4.33

COMPASS CALIBRATION WITH A MAGNETOMETER (OPTION).

Before running the compass calibration, you must turn off the magnetometer uplink.
Open the startup.ini file in the klein directory, and change the line
set DEFAULTUPLINK 1 to set DEFAULTUPLINK 0.
save startup.ini file.
Run the compass calibration in SonarPro. Once compass has been calibrated, open
the startup.ini file, and change the set DEFAULTUPLINK back to 1.
If trying this method, survey the area first, making sure you have
enough water to operate safely, since the transmitters are turned off.
Compass calibration can also be done manually by selecting: