2
Getting Started
never exceed maximum input power. The recommended input
power operating level for OC-1, OC-3/STM-0, STM-1 signals is
-33 to -10 dBm and for OC-12/STM-4 signals -28 to -8 dBm.
2.5 Gb/s
Selectable optical connector (see "Optical Connectors (prod-
uct options)" on page 13) for a 2.5 Gb/s optical input
(OC-48/STM-16 signals). Wavelength 1200 to 1600 nm. Input
damage power> +3 dBm; never exceed maximum input power.
The recommended input power operating level for
OC-48/STM-16 signals is -28 to -8 dBm.
10 Gb/s High Rx Sensitivity Optics
Selectable optical connector (see "Optical Connectors (prod-
uct options)" on page 13) for 10 Gb/s (OC-192/STM-64) opti-
cal input signals. Wavelength 1200 to 1600 nm. Input damage
power >+1 dBm; never exceed maximum input power. The rec-
ommended input power operating level for OC-192/STM-64
signals is -20 to -9 dBm.
10 Gb/s (SR) Optics
Selectable optical connector (see "Optical Connectors (prod-
uct options)" on page 13) for 10 Gb/s (OC-192/STM-64) opti-
cal input signals. Wavelength 1200 to 1600 nm. Input damage
power >+3 dBm; never exceed maximum input power. The rec-
ommended input power operating level for OC-192/STM-64
(1310 nm) signals is -11 to -1 dBm. The recommended input
power operating level for OC-192/STM-64 (1550 nm) signals is
-14 to -1 dBm.

Clock Ports

2 Mb/s, 2 MHz Clock In
BNC 75 ohm (nominal) unbalanced connector for a 2 Mb/s and
2 MHz MTS external clock source input.
2 Mb/s, 2 MHz Clock In
3-pin Siemens connector for a 2 Mb/s and 2 MHz MTS exter-
nal clock source input.