Raven SCS 660 Installation And Service Manual page 43

Hide thumbs Also See for SCS 660:
Table of Contents

Advertisement

PROCEDURE TO PROGRAM SERIAL 660 FOR NEW LEADER
The initialization for the console should be:
1)
US for acres, pounds, etc.
2)
SP1 or SP2, depending on the truck's speed sensor.
3)
GR1 for single belt.
4)
C-NL1 for "Hall Effect" control valve.
valve.
5)
The rest of the console calibration is the same as described in the SCS 660
GRANULAR APPLICATION manual.
CONSTANT [starting values below], VALVE CAL, RATE 1 CAL, and RATE 2 CAL).
Spreader Constants (for New Leader/HiWay Equipment Co L-3020 box with 0.256 Chain & Belt
Over Chain, Mark IV stepper system only).
first inch of gate opening. The Spreader Constant for a desired gate height is determined
by dividing 1172 by the exact gate opening.
your convenience.
2"
gate = 586
4"
gate = 293
6"
gate = 195
8"
gate = 147
10" gate = 117
Spreader Constants (for New Leader/HiWay Equipment Co L-2020 box with 0.192 Chain & Belt
Over Chain, Mark IV stepper systems only). Starting Spreader Constant is 1563 for the
first inch of gate opening. The Spreader Constant for a desired gate height is determined
by dividing 1563 by the exact gate opening.
your convenience.
2"
gate = 782
4"
gate = 391
6"
gate = 261
8"
gate = 195
10" gate = 156
NOTE: Verify Spreader Constant by performing Spreader Constant calibration
procedure in Appendix 5 before field application.
APPENDIX 6
MARK IV INTERFACE
(BOOM CAL, SPEED CAL, METER CAL, SPREADER
Starting Spreader Constant is 1172 for the
One inch increments are listed below for
3"
gate = 391
5"
gate = 234
7"
gate = 167
9"
gate = 130
One inch increments are listed below for
3"
gate = 521
5"
gate = 313
7"
gate = 223
9"
gate = 174
41
C-NL2 for "Reed Switch" control