The icons used in the Dryer overview screen (ES_6) are as follows:
Icon
2212 0215 19
Status
Compressor Shutdown
Failed to go on load
Overload
Element temperature
warning
Aftercooler temperature
warning
Sensor error
Local mode
Service required
Isolated
Status
Dryer is operational
Dryer is in purge saving
Dryer is in economy
saving
Dryer is in standby
Description
Compressor is in Shutdown condition.
The pressure switch at the compressor outlet detects a too low
pressure when it should not.
The motor draws too much current and the overload has
isolated the compressor.
The compressor element outlet temperature is too high
The compressor aftercooler temperature is too high
The compressor has a sensor error.
The compressor has either been manually set to local, was
forced locally from an ES command, or was forced locally by
the Emergency Forced Local backup system.
The compressor's running hours have surpassed the
predefined interval and maintenance must be carried out.
User has isolated this compressor controller. It will not transmit
faults or alarms.
Description
The dryer is delivering conditioned air to the system.
The dryer is in purge saving mode, operating its solenoid
valves based on the dew point.
The dryer is in economy mode, operating its solenoid valves
based on the working status of all connected compressors.
The dryer is in standby mode, ready to be switched on.