Precautions For Powering Off Only A Desired Servo Amplifier - Mitsubishi Electric Q172DCPU Migration Manual

Motion controller
Hide thumbs Also See for Q172DCPU:
Table of Contents

Advertisement

1. OVERVIEW OF MIGRATION FROM Q17nDCPU(-S1) TO Q17nDSCPU

1.4.4 Precautions for powering off only a desired servo amplifier

Use the SSCNETIII/H compatible MR-MV200 optical hub unit for powering off only a desired
servo amplifier.
Refer to section 1.4.5 for details of the MR-MV200 optical hub unit.
The system with the MR-MV200 is shown below.
Optical hub unit
MR-MV200
Servo amplifier
MR-J4-B
Servo motor
HG series
1 - 12