46/65
Assembly
7.2.7

Plug connector protective cover

Bosch Rexroth AG R911387136_Edition 02
Protect the connector from external force effect.
Observe the general installation conditions.
Please observe the special conditions on use "X" for tensile load
and impact test.
II 3G:
chapter 5.1.1 "Special conditions on use X (gas)" on page 26
II 3D:
chapter 5.2.1 "Special conditions on use X (gas)" on page 29
Mounting instructions for single cable connection plug-connector
Motor types: MS2Exx-xxxxN-CxSxx-NNNNN-NN
Cable types: RH2-xxxxx-NN-xxx,x
Ready-made connection cables are provided for single cable connection. Be‐
fore assembly, compare the type designations of motor and cable.
1. Connect the cable connector to the motor connector. Observe, the
knurled nut of the cable connector in "open" position. Only in this posi‐
tion, the cable connector can be slided on. Avoid any kind of force.
Fig. 7-3:
Connect Speedcon quick lock
2. Tighten the knurled nut of the cable connector with a 90° turn.
Fig. 7-4:
Lock Speedcon quick lock
3. Check the firm seat of the SpeedCon quick lock by short pull on the con‐
nector.
4. Secure the cable to prevent accruing forces due to cable vibrations onto
the connector.
SUP-M01-MS2E plug connector protective cover is available as an optional
accessory.
Order number
R911404719
R911392284
The plug connector protective cover fulfills the required protection against im‐
pact onto the plug connector according to the ATEX directive. In the special
conditions on use "X" we refer to the responsibility of the plant manufacturer
to do a risk evaluation.
MS2E Synchronous Servomotors acc. to ATEX Directive
Designation
SUP-M02-MS2E
SUP-M01-MS2E
2014/34/EU
Size
M17
M23