Connecting The Electric Supply; Safety - Bosch REXROTH MS2E Operating Instructions Manual

Synchronous servomotors
Hide thumbs Also See for REXROTH MS2E:
Table of Contents

Advertisement

42/65
Assembly
7.2

Connecting the electric supply

7.2.1

Safety

Bosch Rexroth AG R911387136_Edition 02
Fitting
Fig. 7-1:
Fitting the transmission element
Use the centering hole for fitting transmission elements. For details on cen‐
tering holes, please refer to the project planning manual. If necessary, heat‐
ing up the transmission element.
WARNING
Work required on the electric system may only be carried out
by skilled electricians. Tools for electricians (VDE tools) are
absolutely necessary.
Prior to commencing work:
DANGER
Make sure that the motor is only connected in the de-energized state
and a non-explosive atmosphere.
Before working on the system, always use a suitable measuring instru‐
ment (e.g. multimeter) to check whether parts are still under a residual
voltage (e.g. due to the residual energies of capacitors in filters, drive
devices, etc.); let their discharge times elapse.
The connection between the grounding conductor and the system
ground must be made before any other connections.
The junctions to or on the control device must be situated outside a haz‐
ardous area or be licensed for the use in hazardous areas.
MS2E Synchronous Servomotors acc. to ATEX Directive
Danger! Electric voltage! Operations in the vi‐
cinity of live parts are extremely dangerous.
1. Isolate (even auxiliary circuits).
2. Secure against reactivation.
3. Ensure de-energization.
4. Ground and short-circuit.
5. Cover or shield any adjacent live parts.
Explosion hazard due to improper handling
during the connection of the motor!
2014/34/EU

Advertisement