Assembly

6.2.11 Plug-in connector with threaded connection

WARNING
Connect and disconnect connectors only when they are dry and de-energized.
During operation of the system, all connectors must be securely tightened or
locked.
Observe when connecting the flange sockets:
Protect the flange sockets from external force effect.
Connect the motor to ready-made connection cables.
Connect the plug-in connector with the threaded connector M58
Before connecting, please ensure properly measured ready-made connection cables
are available. The type, size and cable cross section of the plug-in connector must
be adjusted to the motor.
1. Position power connector at thread.
2. Tighten knurled nut "securely", in doing so, retrace cable.
3. Check the firm seat of the connection by short pull on the connector.
4. Secure the cables, that accruing forces due to cable vibrations onto the
connector are prevented.
Bosch Rexroth AG R911347581_Edition 04
MS2N Synchronous Servomotors
Damage to persons or property by disconnect-
ing or connecting energized connectors!