Toshiba TE Series Instruction Manual page 35

Low voltage digital solid state soft starter 18 – 1250a
Hide thumbs Also See for TE Series:
Table of Contents

Advertisement

Basic Installation and Operation Guide
Example 1: Figure 5.4.3
Viewing a Function's Set Value
[0000.] Indicates Phase A is drawing no current
(unit is in Off mode).
Press the [Fn] key
[F001]
Indicates this is Function 001 (Motor FLA).
Press [READ/ENTER] key
to view the F001 value
[0048]
Indicates the programmed motor FLA is 48 Amps.
The right most digit (8) is flashing, indicating that
this is the digit that you will alter (cursor position).
Press the UP Arrow key
to increase this digit value
[0049]
Indicates you have increased the right most digit
to a value of 9.
Press the LEFT Arrow key
to shift left to the next digit
[0049]
The second digit from the right is now flashing,
indicating a new cursor position.
Press the UP Arrow key
to increase this digit value
[0059]
Indicates you have increased the 2
to a value of 5 (10's place).
Press [READ/ENTER] key
to store the new value
[End]
The word "End" will flash briefly to indicate that
the new value has been entered and accepted.
After flashing once, the display will revert to
showing the Function number.
26 |
P a g e
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
TE Series Digital Solid State Soft Starters 18 – 1250A
5.4.2
Enabling Password Protection / Parameter Lock
TE Series starter is shipped with the password protection disabled (F070
= 0). If it becomes necessary to prevent parameters from being changed
inadvertently, set the password in function F070. See Appendix 3 for
details. If the display reads [Loc] when the [READ/ENTER] key is
pressed, the parameter lock is enabled.
5.4.3
Changing a Function's Set Value
After pressing the [READ/ENTER] key the display will show the value of
that function with one digit flashing (usually the rightmost digit). Flashing
indicates this is the digit to be altered (similar to cursor position). Use the
UP arrow key to increment the value of the flashing digit. Use the DOWN
arrow key to decrement the value of the flashing digit. Use the LEFT or
RIGHT arrow to select the next digit to be altered. Values can only be
changed within the Adjustment Range of the function parameter.
nd
to right digit
Example 1: Setting the Motor FLA
Change FLA from 48 to 59A
Display
Means...
Shows...
Phase A
0000.
Press
Current
Key...
Function #1
F001
Fn
Selected
Previous Setting
READ
0048
ENTER
of Function #1
New Value of
0049
First Digit
Cursor (flashing)
0049
Position Shift
New Value of
0059
Second Digit
Value Accepted
READ
End
ENTER
(flashes once)
Return to
F001
Function # Display
Figure 5.4.3:
Changing a Function Value

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents