Agilent Technologies E1476A User Manual page 64

64-channel, 3-wire multiplexer module
Table of Contents

Advertisement

&281W  _ 0,1 _ 0$;
SAMPle
&281W" >0,1 _ 0$;@
6285FH ,00 _ 7,0
6285FH"
7,0HU  PV   PV _ 0,1 _ 0$;
7,0HU" >0,1 _ 0$;@
)81&WLRQ>IXQFWLRQ!@
[SENSe:]
)81&WLRQ"
5(6LVWDQFH$3(5WXUH WLPH! _ 0,1 _ 0$;
5(6LVWDQFH$3(5WXUH" >0,1 _ 0$;@
5(6LVWDQFH13/& QXPEHU! _ 0,1 _ 0$;
5(6LVWDQFH13/&" >0,1 _ 0$;@
5(6LVWDQFH2&20SHQVDWHG 2)) _  _ 21 _ 
5(6LVWDQFH2&20SHQVDWHG"
5(6LVWDQFH5$1*H UDQJH! _ 0,1 _ 0$;
5(6LVWDQFH5$1*H" >0,1 _ 0$;@
5(6LVWDQFH5$1*H$872 2)) _  _ 21 _ 
5(6LVWDQFH5$1*H$872"
5(6LVWDQFH5(6ROXWLRQ UHVROXWLRQ! _ 0,1 _ 0$;
5(6LVWDQFH5(6ROXWLRQ" >0,1 _ 0$;@92/7DJH$&
5$1*H UDQJH! _ 0,1 _ 0$;
92/7DJH$&5$1*H" >0,1 _ 0$;@
92/7DJH$3(5WXUH WLPH! _ 0,1 _ 0$;
92/7DJH$3(5WXUH" >0,1 _ 0$;@
92/7DJH>'&@5$1*H UDQJH! _ 0,1 _ 0$;
92/7DJH>'&@5$1*H" >0,1 _ 0$;@
92/7DJH13/& QXPEHU! _ 0,1 _ 0$;
92/7DJH13/&" >0,1 _ 0$;@
92/7DJH5$1*H$872 2)) _  _ 21 _
92/7DJH5$1*H$872"
92/7DJH5(6ROXWLRQ UHVROXWLRQ!
92/7DJH5(6ROXWLRQ" >0,1 _ 0$;@
&'(6FULSWLRQ" FDUGBQXPEHU!
SYSTem
&7<3H" FDUGBQXPEHU!
(55RU"
&281W  _ 0,1 _ 0$;
TRIGger
&281W" >0,1 _ 0$;@
'(/D\  _ 0,1 _ 0$;
'(/D\" >0,1 _ 0$;@
'(/D\$872 2)) _  _ 21 _ 
'(/D\$872"
>,00HGLDWH@
6285FH %86 _ (;7 _ +2/' _ ,00 _ 77/7UJ77/7UJ
6285FH"
Chapter 3
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Command
Description
Set number of readings per trigger
Query number of readings per trigger
Set pacing source
Query pacing source
Define period between readings
Query period between readings
Select measurement function
Query measurement function
Set aperture (integration) time in sec
Query aperture (integration) time
Set integration time in PLCs
Query integration time
Enable/disable offset compensation
Query offset compensation mode
Select range
Query range
Enable/disable autorange function
Query autorange mode
Specify resolution
Query resolution
Select measurement range
Query range
Set aperture (integration) time in sec
Query aperture (integration) time
Select range
Query range
Set integration time in PLCs
Query integration time
Enable/disable autoranging
Query autorange mode
Specify resolution
Query resolution
Return description of multiplexer in
scanning multimeter
Return card type of multiplexer in
scanning multimeter
Return error number/message from
error queue
Set number of triggers or scans
Query trigger count
Set delay between trigger and start of
measurement
Query trigger delay
Enable/disable automatic trigger delay
Query automatic trigger delay mode
Trigger immediately
Specify trigger source
Query trigger source
Scanning Voltmeter Applications 63

Advertisement

Table of Contents
loading

Table of Contents