Clean: PATCH CORD
CleanBlast
Advanced Fiber End Face Cleaning System
1.
Install the appropriate cleaning tip and
adapter (fCLT-U25 and fCLT-U25-MA shown)
to the CleanBlast handset.
Note: Patch cord cleaning requires a mating
adapter (see Appendix B: Cleaning Tips &
Adapters Guide on page 27).
PRImE
PRImE / PuRgE the nozzle to clear the solvent line if
you are using the system for the first time, after refill,
or if the system has been powered oFF for more than
4 hours.
A.
Push the prime button quickly 2 times.
B.
Aim the tip away from any surfaces or objects.
C.
Press the run button on the handset.
D.
Repeat steps A through C at least 2 more times.
2.
Attach the patch cord to the handset, push
the connector into the handset to disengage
safety mechanism (the POWER/READY light
will turn green), and press the run button to
initiate cleaning.
3.
INSPECT
the patch cord.
4.
Determine whether clean or dirty.
 If clean, do not touch it and CONNECT.
 If dirty, repeat
Note: Embedded/mated debris cannot be
cleaned, and bonded/burned debris must be
physically cleaned before using CleanBlast.
CleanBlast – PortaBle
CLEAN.
Adapter
Cleaning Tip
(FCLT-U25-MA)
(FCLT-U25)
2
4
CLEAN
1
Prime Button
(press 2 times)
run Button
run Button
3
17