aCCePtanCe CrIterIa
The tables below list the acceptance criteria standardized by the International
Electrotechnical Commission (IEC) for single-mode and multimode connectors as
documented in IEC 61300-3-35 Ed. 1.0.
SINgLE-mODE CONNECTORS
Zone Name
A. CORE Zone
B.
CLADDINg Zone
C.
ADhESIvE Zone
D. CONTACT Zone
muLTImODE CONNECTORS
Zone Name
A. CORE Zone
B.
CLADDINg Zone
C.
ADhESIvE Zone
D. CONTACT Zone
CleanBlast – PortaBle
Diameter
Defects
0 – 25 μm
none
no limit < 2 μm
25 –120 μm
5 from 2 – 5 μm
none > 5 μm
120 – 130 μm
no limit
130 – 250 μm
none => 10 μm
Diameter
Defects
4 <= 5 μm
0 – 65 μm
none > 5 μm
no limit < 2 μm
65 –120 μm
5 from 2 – 5 μm
none > 5 μm
120 – 130 μm
no limit
130 – 250 μm
none => 10 μm
IS IT CLEAN
Scratches
none
no limit <= 3 μm
none > 3 μm
no limit
no limit
Scratches
no limit <= 5 μm
0 > 5 μm
no limit <= 5 μm
0 > 5 μm
no limit
no limit
15