Heater Priority - LG THERMA V Installation Manual

Air-to-water heat pump
Hide thumbs Also See for THERMA V:
Table of Contents

Advertisement

INSTALLER SETTING
238

Heater priority

• Heater priority : determine electric heater and DHW tank heater on and off.
• Example : If Heater priority is set as 'Main+Boost heater ON', then electric heater and DHW
tank heater are on and off according to control logic. If Heater priority is set as 'Boost heater
only ON', then electric heater is never turned on and only DHW tank heater is on and off
according to control logic.
• In the installer setting list, heater priority category, and press [OK] button to move to the detail
screen.
Value
Boost heater only ON
OK
Main+Boost heater ON

Advertisement

Table of Contents
loading

Table of Contents