Heater priority

• Heater priority : determine electric heater and DHW tank heater on and off.
• Example : If Heater priority is set as 'Main+Boost heater ON', then electric heater and DHW
tank heater are on and off according to control logic. If Heater priority is set as 'Boost heater
only ON', then electric heater is never turned on and only DHW tank heater is on and off
according to control logic.
• In the installer setting list, heater priority category, and press [OK] button to move to the detail
screen.
Value
Boost heater only ON
INSTALLER SETTING
OK
Main+Boost heater ON
111