Dhw Tank - LG THERMA V Installation Manual

Air-to-water heat pump
Hide thumbs Also See for THERMA V:
Table of Contents

Advertisement

ACCESSORIES INSTALLATION
110

DHW Tank

To establish DHW circuit, 3way valve and DHW tank kit is required. If solar thermal system is
pre-installed at the installation field, solar thermal kit is required to interface solar thermal
system – to – DHW tank – to –
Installation condition
Installing sanitary water tank requires following considerations :
- Sanitary water tank should be located at the flat place.
- Water quality should be complied with EN 98/83 EC directives.
- As this water tank is sanitary water tank (indirect heat exchange), do not use anti water-freezing
treatment like ethylene grycol.
- It is highly recommend to wash out inside of the sanitary water tank after installation. It ensures
generating clean hot water.
- Near the sanitary water tank there should be water supply and water drain to easy access and
maintenance.
- Set the maximum value of the temperature control device of sanitary tank.
Water Tank Sensor
(Less than 12 m)
Water In
Water Out
General Information
supports following 3way valve.
Type
Power
SPDT
230 V AC
3-wire
(1)
(1) : SPDT = Single Pole Double Throw. Three wires consist of Live1 (for selecting Flow A), Live 2
(for selecting Flow B), and Neutral (for common).
(2) : 'Flow A' means water flow from the unit to under floor water circuit.
(3) : 'Flow B' means water flow from the unit to DHW tank.
Solar Thermal Sensor
(Less than 12 m)
3way valve
(Field Supply)
Pump
(Field Supply)
Water Tank
Operating Mode
Selecting "Flow A" between
"Flow A" and "Flow B" (2)
Selecting "Flow B" between
"Flow A" and "Flow B" (3)
Solar
Thermal
Water In
System
Water Out
(Field Supply)
Supported
Yes
Yes
Solar
Collector
(Field Supply)

Advertisement

Table of Contents
loading

Table of Contents