Dhw Tank And Dhw Tank Kit/Solar Thermal Kit; General Information - LG THERMA V Installation Manual

Air-to-water
Hide thumbs Also See for THERMA V:
Table of Contents

Advertisement

1,MFL68681810,영영 2017. 7. 1. 영영 12:55 Page 57

DHW Tank and DHW Tank Kit/Solar Thermal Kit

To establish DHW circuit, 3way valve and DHW tank kit is required. If solar thermal system is pre-
installed at the installation field, solar thermal kit is required to interface solar thermal system – to –
DHW tank – to –

General Information

supports following 3way valve.
Type
Power
SPDT
230V AC
3-wire
(1)
(1) : SPDT = Single Pole Double Throw. Three wires consist of Live1 (for selecting Flow A), Live 2
(for selecting Flow B), and Neutral (for common).
(2) : 'Flow A' means water flow from the indoor unit to under floor water circuit.
(3) : 'Flow B' means water flow from the indoor unit to DHW tank.
Operating Mode
Selecting " Flow A" between
" Flow A" and " Flow B" (2)
Selecting " Flow B" between
" Flow A" and " Flow B" (3)
Accessories Installation
Supported
Yes
Yes
Installation Manual 57

Advertisement

Table of Contents
loading

Table of Contents