Warranty; Technical Specifications - STEINEL iHF 3D Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 9
8
Install mode
Install mode has the purpose of
checking for proper working order
as well for testing the detection zone.
Irrespective of light level, the light
switches ON for 10 s in response to
movement. (Status LED flashes).
Install mode has priority over all
other settings. Install mode ends
automatically after 10 min. Install
mode ends immediately after
pressing reset.
Note: Teach mode and Install
mode cannot be used at one
at the same time.
Reset
9
Resets all settings to the values
selected on the light manually or
to the factory settings.
Smart Remote (optional)
(EAN 4007841009151)
– Control by smartphone or tablet
– Replaces remote control
– Load appropriate app and connect via
Bluetooth
8� EC Declaration of Conformity
This product complies with the requirements
defined in the following standards, legislation
and directives:
– Low Voltage Directive 2014/35/EC
– EMC Directive 2014/30/EC
– RoHS Directive 2011/65/EU
– Directive on Waste Electrical and Electronic
Equipment WEEE 2012/19/EU
9� Warranty
All rights are based on our guarantee period.
We guarantee that your STEINEL Professional
sensor product will remain in perfect condition
and proper working order for a period of
5 years. We guarantee that this product is
free from material, manufacturing and design
flaws. In addition, we guarantee that all elec-
tronic components and cables function in the
proper manner and that all materials used and
their surfaces are without defects.
Making Claims
If you wish to make a claim, please send your
product complete and carriage paid with the
original receipt of purchase, which must show
the date of purchase and product designation,
either to your retailer or contact us at STEINEL
(UK) Limited, 25 Manasty Road, Axis Park,
Orton Southgate, Peterborough, PE2 6UP,
for a returns number. For this reason, we re-
commend that you keep your receipt of pur-
chase in a safe place until the warranty period
expires. STEINEL shall assume no liability
for the costs or risks involved in returning a
product.
For information on making claims under
the terms of the warranty, please go to
www�steinel-professional�de/garantie
If you have a warranty claim or would like to
ask any question regarding your product,
you are welcome to call us at any time on our
service hotline 01733 366700.
18

10. Technical specifications

Dimensions (W x D x H):
117 x 120 x 120 mm
Mains voltage:
220 - 240 V / 50/60 Hz
Output:
Bulbs,
2000 W max. at 230 V *
Fluorescent tube, 1000 VA max.
at 230 V (cos j = 0.5)
Starting current:
max. 800 A / 200 μs
Electronic ballast *
30 x (1 x 18 W), 25 x (2 x18 W)
25 x (1 x 36 W), 15 x ( 2 x 36 W)
20 x (1 x 58 W), 10 x (2 x 58 W)
Angle of coverage:
160°
Sensor technology:
5.8 GHz
Reach:
1 - 5 m (approx. 7 m max.), in 3 directions
Time setting:
30 s - 30 min, 10 s - 30 min (by remote control RC9)
Manual override:
selectable (4h)
Light-level setting:
2-1000 lux
Max. area covered:
approx. 68 m²
IP rating:
IP 54
Temperature range:
-20° to +50°C
*1)
VDE-tested
*2)
Fluorescent lamps, low-energy lamps, LED lights with electronic ballast
(total capacity of all ballasts connected below the level stated).
11. Troubleshooting
Malfunction
Cause
Sensor without power
n Fuse faulty, not switched
ON, break in wiring
n Short circuit
Sensor will not switch ON
n Twilight setting in night mode
during daytime operation
n Bulb faulty
n Mains power switch OFF
n Fuse faulty
n Detection zone not properly
targeted
Sensor will not switch OFF
n Continuous movement in
the detection zone
Sensor keeps switching ON/OFF
n Light being operated is
located in detection zone
1)
2)
:
Remedy
n New fuse, turn ON power
switch, check wiring with
voltage tester
n Check connections
n Adjust setting
n Change bulb
n Switch ON
n Fit new fuse, check
connection if necessary
n Readjust
n Check zone, adjust or fit
shrouds if necessary
n Change zone, or fit shrouds
n Deactivate 4 h manual
override
n Change zone or fit shrouds,
increase distance
19

Advertisement