Electrical function test ......................12 System status table .................... 13 Technical data ....................14 11.1. Technical data for safety switch CES-I-AS2A-C04 ................14 11.1.1. Dimension drawing of safety switch CES-I-AS2A-C04 ............15 11.2. Typical system times ........................15 11.3. Technical data for actuator CES-A-BBN-C04 ..................16 11.3.1.
Page 3
Operating Instructions Non-Contact Safety Switch CES-I-AS2A-C04 11.4. Technical data for actuator CES-A-BDN-06 ..................18 11.4.1. Dimension drawing ......................18 11.4.2. Operating distances ......................18 Ordering information and accessories ..............19 Inspection and service ..................19 Service ......................19 Declaration of conformity ................... 20...
Non-Contact Safety Switch CES-I-AS2A-C04 1. About this document 1.1. Scope These operating instructions are valid for all CES-I-AS2A-C04. These operating instructions, the document Safety information and any enclosed data sheet form the complete user information for your device. 1.2. Target group Design engineers and installation planners for safety devices on machines, as well as setup and servicing staff possessing special expertise in handling safety components.
Ì EN ISO 14119 Ì EN 60204-1 The safety switch must be used only in conjunction with the designated CES actuators from EUCHNER. On the use of different actuators, EUCHNER provides no warranty for safe function. Important! Ì The user is responsible for the proper integration of the device into a safe overall system. For this purpose, the overall system must be validated, e.g.
Operating Instructions Non-Contact Safety Switch CES-I-AS2A-C04 3. Description of the safety function Devices from this series feature the following safety functions: Monitoring of the guard position (interlocking device according to EN ISO 14119) Ì Safety function: When the guard is open, no valid code sequence is sent (see chapter 6.2. Switching states on page 7).
Operating Instructions Non-Contact Safety Switch CES-I-AS2A-C04 6. Function The safety switch monitors the position of movable guards. When the actuator is moved to/removed from the actuating range, a corresponding bit sequence is sent via the AS-Interface bus. The system consists of the following components: coded actuator (transponder) and switch.
Operating Instructions Non-Contact Safety Switch CES-I-AS2A-C04 7. Mounting CAUTION Safety switches must not be bypassed (bridging of contacts), turned away, removed or otherwise rendered ineffective. Ì Observe EN ISO 14119:2013, section 7, for information about reducing the possibilities for by- passing an interlocking device.
Operating Instructions Non-Contact Safety Switch CES-I-AS2A-C04 8. Electrical connection View of plug connector Safety switch 1 AS-Interface + 3 AS-Interface - 4 Not used Figure 1: Terminal assignment, AS-Interface M8 plug connector CAUTION Risk of damage to equipment or malfunctions as a result of incorrect connection.
Operating Instructions Non-Contact Safety Switch CES-I-AS2A-C04 8.2. Setting the AS-Interface address The address can be set prior to or after mounting. The AS-Interface address of the safety switch is set using an AS-Interface programming device. Addresses 1 to 31 are valid.
Operating Instructions Non-Contact Safety Switch CES-I-AS2A-C04 9. Setup 9.1. LED displays You will find a detailed description of the signal functions in chapter 10. System status table on page 13. LEDs Color STATE green 9.2. Teach-in function for actuator (only for unicode evaluation) The actuator must be allocated to the safety switch using a teach-in function before the system forms a functional unit.
Operating Instructions Non-Contact Safety Switch CES-I-AS2A-C04 9.3. Functional check WARNING Danger of fatal injury as a result of faults in installation and functional check. Ì Before carrying out the functional check, make sure that there are no persons in the danger zone.
Operating Instructions Non-Contact Safety Switch CES-I-AS2A-C04 10. System status table CES LED indicator Output Operating mode State closed Normal operation, door closed Flash burst closed inverse Normal operation, door closed, actuator in the limit range Re-adjust door ¨ Normal operation...
Operating Instructions Non-Contact Safety Switch CES-I-AS2A-C04 11. Technical data NOTICE If a data sheet is included with the product, the information on the data sheet applies. 11.1. Technical data for safety switch CES-I-AS2A-C04 Parameter Value Unit min. typ. max. Housing material...
Operating Instructions Non-Contact Safety Switch CES-I-AS2A-C04 11.1.1. Dimension drawing of safety switch CES-I-AS2A-C04 10,6 14,5 15,5 With rubber support Rubber support (included) 11.2. Typical system times Refer to the technical data for the exact values. Ready delay: After switch-on, the device carries out a self-test. The system is ready for operation only after this time.
Operating Instructions Non-Contact Safety Switch CES-I-AS2A-C04 11.3. Technical data for actuator CES-A-BBN-C04 Value Parameter Unit min. typ. max. Housing material PBT plastic Rubber-support material NBR 80 ±5 Shore Dimensions 42 x 25 x 18 Weight 0.03 Ambient temperature - 40 + 65 °C...
Operating Instructions Non-Contact Safety Switch CES-I-AS2A-C04 11.4. Technical data for actuator CES-A-BDN-06 Parameter Value Unit min. typ. max. Housing material Macromelt PA-based plastic Dimensions 26 x ∅ 6 Weight 0.005 Ambient temperature - 40 + 70 °C Degree of protection...
12. Ordering information and accessories Tip! Suitable accessories, e.g. cables or assembly material, can be found at www.euchner.com. To order, enter the order number of your item in the search box and open the item view. Accessories that can be combined with the item are listed in Accessories.
Operating Instructions Non-Contact Safety Switch CES-I-AS2A-C04 15. Declaration of conformity (Translation of the original operating instructions) 2120544-07-07/20...
Page 21
Operating Instructions Non-Contact Safety Switch CES-I-AS2A-C04 2120544-07-07/20 (Translation of the original operating instructions)
Page 22
Operating Instructions Non-Contact Safety Switch CES-I-AS2A-C04 (Translation of the original operating instructions) 2120544-07-07/20...
Page 23
Operating Instructions Non-Contact Safety Switch CES-I-AS2A-C04 2120544-07-07/20 (Translation of the original operating instructions)