Technical data ....................13 11.1. Technical data of safety switch CES-I-AS2A-M-C04 ................13 11.1.1. Typical system times ......................14 11.1.2. Dimension drawing of safety switch CES-I-AS2A-M-C04 ............14 11.2. Technical data of actuator CES-A-BBN-C04 ..................15 11.2.1. Dimension drawing ......................15 11.2.2. Switching distances ......................15 11.2.3.
Page 3
Operating Instructions Non-Contact Safety Switch CES-I-AS2A-M-C04 Ordering information and accessories ..............18 Inspection and service ..................18 Service ......................18 Declaration of conformity ................... 19 2120545-05-08/18 (translation of the original operating instructions)
1. About this document 1.1. Scope These operating instructions are valid for all CES-I-AS2A-M-C04. These operating instructions, the document “Safety infor- mation and maintenance” and any enclosed data sheet form the complete user information for your device. 1.2. Target group Design engineers and installation planners for safety devices on machines, as well as setup and servicing staff possessing special expertise in handling safety components.
EN 60204-1, Safety of machinery. Electrical equipment of machines. General requirements. The safety switch must be used only in conjunction with the designated CES actuators from EUCHNER. On the use of different actuators, EUCHNER provides no warranty for safe function.
Prior to use, read the operating instructions and keep these in a safe place. Ensure the operating instructions are always available during mounting, setup and servicing. EUCHNER cannot provide any warranty in relation to the readability of the CD for the storage period required. For this reason you should archive a printed copy of the operating instructions.
Operating Instructions Non-Contact Safety Switch CES-I-AS2A-M-C04 6. Function The safety switch monitors the position of movable safety guards. When the actuator is moved to/removed from the oper- ating distance, a corresponding bit sequence is sent via the AS-Interface bus. The system consists of the following components: coded actuator (transponder) and switch.
Operating Instructions Non-Contact Safety Switch CES-I-AS2A-M-C04 7. Mounting CAUTION Safety switches must not be bypassed (bridging of contacts), turned away, removed or otherwise rendered ineffective. Ì Observe EN ISO 14119:2013, section 7, for information about reducing the possibilities for by- passing an interlocking device.
Operating Instructions Non-Contact Safety Switch CES-I-AS2A-M-C04 8. Electrical connection CAUTION Risk of damage to equipment or malfunctions as a result of incorrect connection. Ì Power devices which are a powerful source of interference must be installed in a separate location away from the input and output circuits for signal processing.
No data exchange between master and slave Cause: slave address = 0 Device fault in the slave. red/green Contact EUCHNER. 8.5. Connector assignment of safety switch CES-I-AS2A-M-C04 View of safety switch plug connector 1 AS-Interface + 3 AS-Interface - 4 Not used...
Operating Instructions Non-Contact Safety Switch CES-I-AS2A-M-C04 9. Setup 9.1. LED indicators You will find a detailed description of the signal functions in chapter 10. System status table on page 12. LEDs Color STATE green 9.2. Initial setup 1. Apply operating voltage to the safety switch.
Operating Instructions Non-Contact Safety Switch CES-I-AS2A-M-C04 10. System status table CES LED indicator Output Operating mode State closed Normal operation, door closed flashing Normal operation closed Normal operation, door closed, actuator in limit range Re-adjust door ¨ quickly open Normal operation, door open closed Defective actuator (e.g.
Operating Instructions Non-Contact Safety Switch CES-I-AS2A-M-C04 11. Technical data NOTICE If a data sheet is included with the product, the information on the data sheet applies. 11.1. Technical data of safety switch CES-I-AS2A-M-C04 Parameter Value Unit min. typ. max. Housing material...
Risk time according to EN 60947-5-3: If an actuator moves outside the operating distance, the zero sequence is sent via the AS-Interface bus. 11.1.2. Dimension drawing of safety switch CES-I-AS2A-M-C04 10,6 14,5 15,5...
Operating Instructions Non-Contact Safety Switch CES-I-AS2A-M-C04 11.2. Technical data of actuator CES-A-BBN-C04 Value Parameter Unit min. typ. max. Housing material Plastic PBT Rubber-support material NBR 80 ±5 Shore Dimensions 42 x 25 x 18 Weight 0.03 Ambient temperature - 40 + 65 °C...
Operating Instructions Non-Contact Safety Switch CES-I-AS2A-M-C04 11.3. Technical data of actuator CES-A-BDN-06 Parameter Value Unit min. typ. max. Housing material Macromelt PA-based plastic Dimensions 26 x ∅ 6 Weight 0.005 Ambient temperature - 40 + 70 °C Degree of protection acc. to EN IEC 60529...
12. Ordering information and accessories Tip! Suitable accessories, e.g. cables or assembly material, can be found at www.euchner.com. To order, enter the order number of your item in the search box and open the item view. Accessories that can be combined with the item are listed under “Accessories”.
Operating Instructions Non-Contact Safety Switch CES-I-AS2A-M-C04 15. Declaration of conformity 2120545-05-08/18 (translation of the original operating instructions)
Page 20
Operating Instructions Non-Contact Safety Switch CES-I-AS2A-M-C04 (translation of the original operating instructions) 2120545-05-08/18...
Page 21
Operating Instructions Non-Contact Safety Switch CES-I-AS2A-M-C04 2120545-05-08/18 (translation of the original operating instructions)
Page 22
Operating Instructions Non-Contact Safety Switch CES-I-AS2A-M-C04 (translation of the original operating instructions) 2120545-05-08/18...
Page 23
Operating Instructions Non-Contact Safety Switch CES-I-AS2A-M-C04 2120545-05-08/18 (translation of the original operating instructions)
Need help?
Do you have a question about the CES-I-AS2A-M-C04 and is the answer not in the manual?
Questions and answers