EUCHNER CES-I-BR-C07 Series Operating Instructions Manual

Non-contact safety switch
Hide thumbs Also See for CES-I-BR-C07 Series:
Table of Contents

Advertisement

Quick Links

Operating Instructions
Non-Contact Safety Switch
EN
CES-I-BR-.-C07-... (Unicode/Multicode)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CES-I-BR-C07 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for EUCHNER CES-I-BR-C07 Series

  • Page 1 Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… (Unicode/Multicode)
  • Page 2: Table Of Contents

    Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… Contents About this document ..................... 4 1.1. Scope ............................4 1.2. Target group ..........................4 1.3. Key to symbols ..........................4 1.4. Supplementary documents ......................4 Correct use ......................5 Description of the safety function ................6 Exclusion of liability and warranty ................. 6 General safety precautions ...................
  • Page 3 Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… Using communication data .................. 20 11.1. Connection to a BR/IO-Link Gateway GWY-CB ..................20 11.2. Connection to a safety relay ESM-CB ....................20 11.3. Overview of the communication data ....................20 11.3.1. Cyclical data (process data) ....................20 11.3.2.
  • Page 4: About This Document

    Always read all documents to gain a complete overview of safe installation, setup and use of the device. The documents can be downloaded from www.euchner.com. For this purpose enter the doc. no. or the order number for the device in the search box.
  • Page 5: Correct Use

    Ì EN 60204-1 The safety switch is only allowed to be operated in conjunction with the intended EUCHNER CES actuators and the related connection components from EUCHNER. On the use of different actuators or other connection components, EUCHNER provides no warranty for safe function.
  • Page 6: Description Of The Safety Function

    Prior to use, read the operating instructions and keep these in a safe place. Ensure the operating instructions are always available during mounting, setup and servicing. You can download the operating instructions from www.euchner.com. (translation of the original operating instructions) 2510145-05-08/21...
  • Page 7: Function

    Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 6. Function The safety switch monitors the position of movable guards. The safety outputs are switched on/off when the actuator is moved into/out of the actuating range. The system consists of the following components: coded actuator (transponder) and switch. Whether the device learns the complete actuator code (unicode) or not (multicode) depends on the respective version.
  • Page 8: Mounting

    Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 7. Mounting CAUTION Safety switches must not be bypassed (bridging of contacts), turned away, removed or otherwise rendered ineffective. Ì Observe EN ISO 14119:2013, section 7, for information about reducing the possibilities for by- passing an interlocking device. NOTICE Risk of damage to equipment and malfunctions as a result of incorrect installation.
  • Page 9: Electrical Connection

    Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 8. Electrical connection The following connection options are available: Ì Separate operation Ì Series connection with wiring in the control cabinet Ì Series connection with Y-distributors Ì Connection without IO-Link communication Ì Connection with IO-Link communication WARNING In the event of a fault, loss of the safety function due to incorrect connection.
  • Page 10: Notes About

    Ì On the use of other connection components, the requirements in the following table apply. EUCHNER provides no warranty for safe function in case of failure to comply with these require- ments. Observe the following requirements with respect to the connecting cables:...
  • Page 11: Connector Assignment Of Safety Switch Ces-I-Br

    Ì Always connect inputs FI1A and FI1B directly to a power supply unit or to outputs FO1A and FO1B of another EUCHNER BR device (series connection). Pulsed signals must not be present at inputs FI1A and FI1B.
  • Page 12: Connection Of A Single Ces-I-Br (Separate Operation)

    The user is responsible for safe integration into the overall system. Detailed application examples can be found at www.euchner.com. Simply enter the order number of your switch in the search box. You will find all available connection examples for the device in Downloads.
  • Page 13: Connection Of Several Devices In A Switch Chain (Series Connection)

    Detailed application examples can be found at www.euchner.com. Simply enter the order number of your switch in the search box. You will find all available connection examples for the device in Downloads.
  • Page 14: Series Connection With Y-Distributors

    Possible output current per channel FO1A/FO1B Max. cable length from the last switch to the control system 0.34 mm² Contact EUCHNER in the following cases: Ì If you connect more than 10 switches in series. Ì If you plan to use a different cable design (cross-section, material, etc.).
  • Page 15: Determining Cable Lengths Using The Example Table

    Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 10.2.2. Determining cable lengths using the example table Example: 6 switches are to be used in series. Cabling with a length of 40 m is routed from a safety relay in the control cabinet to the last switch (#6). Cables with a length of 20 m each are connected between the individual safety switches. = 140 m = 40 m = 5 x 20 m...
  • Page 16: Connector Assignment Of Y-Distributor For Series Connection Without Io-Link Communication

    Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 10.2.3. Connector assignment of Y-distributor for series connection without IO-Link communication Important! Ì The switch chain must always be terminated with bridging plug 097645. Ì All guard locking solenoids are always controlled simultaneously on the use of these Y-distributors in a series connection.
  • Page 17 Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… Fig. 4: Connection example for series connection without IO-Link communication 2510145-05-08/21 (translation of the original operating instructions)
  • Page 18: Connector Assignment Of Y-Distributor For Series Connection With Io-Link Communication

    Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 10.2.4. Connector assignment of Y-distributor for series connection with IO-Link communication Important! Ì The switch chain must always be terminated with bridging plug 097645. Plug connector X1 Y-distributor Plug connector X2 / X3 Plug Socket 157913 Function...
  • Page 19 Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… Fig. 5: Connection example for series connection with IO-Link communication 2510145-05-08/21 (translation of the original operating instructions)
  • Page 20: Using Communication Data

    Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 11. Using communication data A BR/IO-Link Gateway is required to use the device’s communication data and forward them to a higher-level bus system. The following devices are suitable: Ì GWY-CB-1-BR-IO (BR/IO-Link Gateway) Ì ESM-CB (safety relay with integrated BR/IO-Link Gateway) 11.1.
  • Page 21: Acyclical Data (Device Data And Events)

    Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 11.3.2. Acyclical data (device data and events) Table 3: Acyclical data (examples) Command Answer Use in device Meaning Category (number of bytes) classes General information Send device ID-number/ PWR-UP serial number Send device Versions PWR-UP number Complete number of...
  • Page 22: Setup

    Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 12. Setup 12.1. Teach-in function for actuator (only for unicode evaluation) The actuator must be allocated to the safety switch using a teach-in operation before the system forms a functional unit. During a teach-in operation, the safety outputs and the door position signal OD are switched off, i.e. the system is in the safe state.
  • Page 23: Electrical Function Test

    Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 12.2. Electrical function test WARNING Danger of fatal injury as a result of faults in installation and functional check. Ì Before carrying out the functional check, make sure that there are no persons in the danger zone. Ì...
  • Page 24: Status And Error Messages

    Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 14. Status and error messages 14.1. LED indicator LEDs Color STATE green Important! If you do not find the displayed device status in the following tables, this indicates an internal device fault. Contact the manufacturer. LED not illuminated LED illuminated LED illuminated, briefly goes off 1 x...
  • Page 25: Error Messages

    Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 14.3. Error messages knowl- LED indicator edging faults Error Troubleshooting STATE green Teach-in error Actuator removed from the actuating range prior to the end of the Check whether the actuator is outside the actuating 0x1F teach-in operation.
  • Page 26: Acknowledging Error Messages

    Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 14.4. Acknowledging error messages If the DIA LED flashes inversely once, the error message can be acknowledged by opening and closing the guard. If the error is still displayed afterward, a reset must be performed. If the LED DIA is permanently illuminated, the error message can be acknowledged only by a reset.
  • Page 27: Technical Data

    Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 15. Technical data NOTICE If a data sheet is included with the product, the information on the data sheet applies. 15.1. Technical data for safety switch CES-I-BR-C07-… Parameter Value Unit min. typ. max. Housing material Plastic PBT-PC-GF30 Dimensions 40 x 26.5 x 18...
  • Page 28 Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… Reliability values acc. to EN ISO 13849-1:2015 Category Performance Level PL e 6 x 10 Mission time years Reliability values acc. to EN 62061:2005/A2:2015 SILCL3 1) Values at a switching current of 50 mA without taking into account the cable lengths. 2) The reaction time is the time until the moment when at least one of the outputs (FO1A or FO1B) switches off when the actuator is removed from the actuating range, given compliance with all manufac- turer’s specifications.
  • Page 29: Radio Frequency Approvals

    Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 15.1.1. Radio frequency approvals FCC ID: 2AJ58-01 22052-01 FCC/IC-Requirements This device complies with part 15 of the FCC Rules and with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 30: Typical System Times

    Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 15.1.2. Typical system times Refer to the technical data for the exact values. Ready delay: After switch-on, the device carries out a self-test. The system is ready for operation only after this time. Turn-on time of safety outputs: The max. reaction time t is the time from the moment when the actuator is in the actu- ating range to the moment when the safety outputs switch on.
  • Page 31: Technical Data For Actuator Ces-A-Btn-C07

    Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 15.2. Technical data for actuator CES-A-BTN-C07-… Parameter Value Unit min. typ. max. Housing material Plastic PBT-PC-GF30 Dimensions 42 x 25 x 18 Weight 0.03 Ambient temperature - 25 + 65 °C Degree of protection IP65/IP67/IP69/IP69K Installation orientation Active face opposite switch...
  • Page 32: Actuating Ranges And Installation Orientations

    Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 15.2.2. Actuating ranges and installation orientations (only in conjunction with actuator CES-A-BTN-C07) Typical actuating range in installation orientation A - 2 6 - 1 0 - 1 4 - 1 8 - 2 2 - 2 6 - 3 0 Operating distances for approach from x direction without center offset (z, y = 0)*...
  • Page 33 Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… Typical actuating range in installation orientation C - 2 2 - 1 0 - 1 4 Operating distances for approach from x direction without center offset (z, y = 0)* Parameter Value Unit min. typ. max. Operating distances Assured operating distances s Switching hysteresis Assured release distance s...
  • Page 34: Technical Data For Actuator Ces-A-Bdn-06-158210

    Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 15.3. Technical data for actuator CES-A-BDN-06-158210 Parameter Value Unit min. typ. max. Housing material Macromelt PA-based plastic Dimensions 26 x ∅ 6 Weight 0.005 Ambient temperature - 25 + 65 °C Degree of protection IP65/IP67/IP69/IP69K Installation orientation Active face opposite switch...
  • Page 35: Operating Distances

    Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 15.3.2. Operating distances* Actuating range for center offset m = 0 Installation orientation Parameter Value Unit min. typ. max. Operating distances Assured operating distances s Switching hysteresis Assured release distance s - in x direction * The data apply to mounting the actuator in non-metallic surroundings.
  • Page 36: Ordering Information And Accessories

    16. Ordering information and accessories Tip! Suitable accessories, e.g. cables or assembly material, can be found at www.euchner.com. To order, enter the order number of your item in the search box and open the item view. Accessories that can be combined with the item are listed in Accessories.
  • Page 37: Declaration Of Conformity

    80339 München Sede indicata Germany Entidad citada 23.08.2021 - NG -GZ - Blatt/Sheet/ Page/Pagina/ Página 1 Vorlage Rev 01 EUCHNER GmbH + Co. KG Kohlhammerstraße 16 70771 Leinfelden-Echterdingen Tel. +49/711/7597-0 Fax +49/711/753316 www.euchner.de info@euchner.de 2510145-05-08/21 (translation of the original operating instructions)
  • Page 38 Director de desarrollo electrónico Agente documentación 23.08.2021 - NG -GZ - Blatt/Sheet/ Page/Pagina/ Página 2 Vorlage Rev 01 EUCHNER GmbH + Co. KG Kohlhammerstraße 16 70771 Leinfelden-Echterdingen Tel. +49/711/7597-0 Fax +49/711/753316 www.euchner.de info@euchner.de (translation of the original operating instructions) 2510145-05-08/21...
  • Page 39 Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 2510145-05-08/21 (translation of the original operating instructions)
  • Page 40 Edition: 2510145-05-08/21 Title: Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… (translation of the original operating instructions) Copyright: © EUCHNER GmbH + Co. KG, 08/2021 Subject to technical modifications; no responsibility is accept- ed for the accuracy of this information.