Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… Contents About this document ..................... 4 1.1. Scope ............................4 1.2. Target group ..........................4 1.3. Key to symbols ..........................4 1.4. Supplementary documents ......................4 Correct use ......................5 Description of the safety function ................6 Exclusion of liability and warranty ................. 6 General safety precautions ...................
Page 3
Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… Using communication data .................. 20 11.1. Connection to a BR/IO-Link Gateway GWY-CB ..................20 11.2. Connection to a safety relay ESM-CB ....................20 11.3. Overview of the communication data ....................20 11.3.1. Cyclical data (process data) ....................20 11.3.2.
Always read all documents to gain a complete overview of safe installation, setup and use of the device. The documents can be downloaded from www.euchner.com. For this purpose enter the doc. no. or the order number for the device in the search box.
Ì EN 60204-1 The safety switch is only allowed to be operated in conjunction with the intended EUCHNER CES actuators and the related connection components from EUCHNER. On the use of different actuators or other connection components, EUCHNER provides no warranty for safe function.
Prior to use, read the operating instructions and keep these in a safe place. Ensure the operating instructions are always available during mounting, setup and servicing. You can download the operating instructions from www.euchner.com. (translation of the original operating instructions) 2510145-05-08/21...
Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 6. Function The safety switch monitors the position of movable guards. The safety outputs are switched on/off when the actuator is moved into/out of the actuating range. The system consists of the following components: coded actuator (transponder) and switch. Whether the device learns the complete actuator code (unicode) or not (multicode) depends on the respective version.
Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 7. Mounting CAUTION Safety switches must not be bypassed (bridging of contacts), turned away, removed or otherwise rendered ineffective. Ì Observe EN ISO 14119:2013, section 7, for information about reducing the possibilities for by- passing an interlocking device. NOTICE Risk of damage to equipment and malfunctions as a result of incorrect installation.
Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 8. Electrical connection The following connection options are available: Ì Separate operation Ì Series connection with wiring in the control cabinet Ì Series connection with Y-distributors Ì Connection without IO-Link communication Ì Connection with IO-Link communication WARNING In the event of a fault, loss of the safety function due to incorrect connection.
Ì On the use of other connection components, the requirements in the following table apply. EUCHNER provides no warranty for safe function in case of failure to comply with these require- ments. Observe the following requirements with respect to the connecting cables:...
Ì Always connect inputs FI1A and FI1B directly to a power supply unit or to outputs FO1A and FO1B of another EUCHNER BR device (series connection). Pulsed signals must not be present at inputs FI1A and FI1B.
The user is responsible for safe integration into the overall system. Detailed application examples can be found at www.euchner.com. Simply enter the order number of your switch in the search box. You will find all available connection examples for the device in Downloads.
Detailed application examples can be found at www.euchner.com. Simply enter the order number of your switch in the search box. You will find all available connection examples for the device in Downloads.
Possible output current per channel FO1A/FO1B Max. cable length from the last switch to the control system 0.34 mm² Contact EUCHNER in the following cases: Ì If you connect more than 10 switches in series. Ì If you plan to use a different cable design (cross-section, material, etc.).
Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 10.2.2. Determining cable lengths using the example table Example: 6 switches are to be used in series. Cabling with a length of 40 m is routed from a safety relay in the control cabinet to the last switch (#6). Cables with a length of 20 m each are connected between the individual safety switches. = 140 m = 40 m = 5 x 20 m...
Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 10.2.3. Connector assignment of Y-distributor for series connection without IO-Link communication Important! Ì The switch chain must always be terminated with bridging plug 097645. Ì All guard locking solenoids are always controlled simultaneously on the use of these Y-distributors in a series connection.
Page 17
Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… Fig. 4: Connection example for series connection without IO-Link communication 2510145-05-08/21 (translation of the original operating instructions)
Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 10.2.4. Connector assignment of Y-distributor for series connection with IO-Link communication Important! Ì The switch chain must always be terminated with bridging plug 097645. Plug connector X1 Y-distributor Plug connector X2 / X3 Plug Socket 157913 Function...
Page 19
Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… Fig. 5: Connection example for series connection with IO-Link communication 2510145-05-08/21 (translation of the original operating instructions)
Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 11. Using communication data A BR/IO-Link Gateway is required to use the device’s communication data and forward them to a higher-level bus system. The following devices are suitable: Ì GWY-CB-1-BR-IO (BR/IO-Link Gateway) Ì ESM-CB (safety relay with integrated BR/IO-Link Gateway) 11.1.
Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 11.3.2. Acyclical data (device data and events) Table 3: Acyclical data (examples) Command Answer Use in device Meaning Category (number of bytes) classes General information Send device ID-number/ PWR-UP serial number Send device Versions PWR-UP number Complete number of...
Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 12. Setup 12.1. Teach-in function for actuator (only for unicode evaluation) The actuator must be allocated to the safety switch using a teach-in operation before the system forms a functional unit. During a teach-in operation, the safety outputs and the door position signal OD are switched off, i.e. the system is in the safe state.
Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 12.2. Electrical function test WARNING Danger of fatal injury as a result of faults in installation and functional check. Ì Before carrying out the functional check, make sure that there are no persons in the danger zone. Ì...
Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 14. Status and error messages 14.1. LED indicator LEDs Color STATE green Important! If you do not find the displayed device status in the following tables, this indicates an internal device fault. Contact the manufacturer. LED not illuminated LED illuminated LED illuminated, briefly goes off 1 x...
Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 14.3. Error messages knowl- LED indicator edging faults Error Troubleshooting STATE green Teach-in error Actuator removed from the actuating range prior to the end of the Check whether the actuator is outside the actuating 0x1F teach-in operation.
Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 14.4. Acknowledging error messages If the DIA LED flashes inversely once, the error message can be acknowledged by opening and closing the guard. If the error is still displayed afterward, a reset must be performed. If the LED DIA is permanently illuminated, the error message can be acknowledged only by a reset.
Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 15. Technical data NOTICE If a data sheet is included with the product, the information on the data sheet applies. 15.1. Technical data for safety switch CES-I-BR-C07-… Parameter Value Unit min. typ. max. Housing material Plastic PBT-PC-GF30 Dimensions 40 x 26.5 x 18...
Page 28
Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… Reliability values acc. to EN ISO 13849-1:2015 Category Performance Level PL e 6 x 10 Mission time years Reliability values acc. to EN 62061:2005/A2:2015 SILCL3 1) Values at a switching current of 50 mA without taking into account the cable lengths. 2) The reaction time is the time until the moment when at least one of the outputs (FO1A or FO1B) switches off when the actuator is removed from the actuating range, given compliance with all manufac- turer’s specifications.
Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 15.1.1. Radio frequency approvals FCC ID: 2AJ58-01 22052-01 FCC/IC-Requirements This device complies with part 15 of the FCC Rules and with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation.
Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 15.1.2. Typical system times Refer to the technical data for the exact values. Ready delay: After switch-on, the device carries out a self-test. The system is ready for operation only after this time. Turn-on time of safety outputs: The max. reaction time t is the time from the moment when the actuator is in the actu- ating range to the moment when the safety outputs switch on.
Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 15.2. Technical data for actuator CES-A-BTN-C07-… Parameter Value Unit min. typ. max. Housing material Plastic PBT-PC-GF30 Dimensions 42 x 25 x 18 Weight 0.03 Ambient temperature - 25 + 65 °C Degree of protection IP65/IP67/IP69/IP69K Installation orientation Active face opposite switch...
Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 15.2.2. Actuating ranges and installation orientations (only in conjunction with actuator CES-A-BTN-C07) Typical actuating range in installation orientation A - 2 6 - 1 0 - 1 4 - 1 8 - 2 2 - 2 6 - 3 0 Operating distances for approach from x direction without center offset (z, y = 0)*...
Page 33
Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… Typical actuating range in installation orientation C - 2 2 - 1 0 - 1 4 Operating distances for approach from x direction without center offset (z, y = 0)* Parameter Value Unit min. typ. max. Operating distances Assured operating distances s Switching hysteresis Assured release distance s...
Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 15.3. Technical data for actuator CES-A-BDN-06-158210 Parameter Value Unit min. typ. max. Housing material Macromelt PA-based plastic Dimensions 26 x ∅ 6 Weight 0.005 Ambient temperature - 25 + 65 °C Degree of protection IP65/IP67/IP69/IP69K Installation orientation Active face opposite switch...
Operating Instructions Non-Contact Safety Switch CES-I-BR-.-C07-… 15.3.2. Operating distances* Actuating range for center offset m = 0 Installation orientation Parameter Value Unit min. typ. max. Operating distances Assured operating distances s Switching hysteresis Assured release distance s - in x direction * The data apply to mounting the actuator in non-metallic surroundings.
16. Ordering information and accessories Tip! Suitable accessories, e.g. cables or assembly material, can be found at www.euchner.com. To order, enter the order number of your item in the search box and open the item view. Accessories that can be combined with the item are listed in Accessories.