4.1.3 INSTALLATION THE iUP250LE PIN PAD IN A NEW KIOSK

The iUP requires standards hexagonal nuts for integration
into a kiosk.
Screw the 4 nuts with a 1.0 Nm torque.
Picture showing a new installation of the iUP250 LE
89.5 mm
50.8 mm
The outside "holes" on the bottom are not
available for mounting! Please use the inner
holes at a distance of 50.8 mm.
It is recommended to use threadlocker fluid to prevent
u nscrewing with vibrations.
To be able to perform the commissioning procedure the
PIN pad must be correctly mounted in the a nti-removal
switch area.
Anti-removal switch area