Table 10. Auto In Service Status Indications - ADTRAN HDSL4 Installation And Maintenance Manual

Hdsl4 for general distribution
Hide thumbs Also See for HDSL4:
Table of Contents

Advertisement

Control Port Operation
The T1 alarm indications displays if the External Alarms option is
set to "Enabled" on the Provisioning menu
The Auto In Service Status screen also indicates the startup or exit period remaining as either
1, 4, 8, or 24 hours. This is the time during which the unit monitors both loop synchroni-
zation (Loop Sync) and T1 alarms (if enabled) and only goes into (or out of) service if the circuit
remains synchronized and without T1 alarms during the entire measured period. These times
are also set from the Provisioning menu
A link is provided to view the Alarm History Screen. The Alarm History Screen screen is also
available by selecting the HDSL4 Main Menu opti
System responses displayed in the status fields on the Alarm History Screen are shown in
Table
10.
Status Field Name
Current Auto In Service State (line 1)
Auto In Service Status (line 2)
Auto In Service Criteria (line 3)
Criteria (current status)
30
.

Table 10. Auto In Service Status Indications

HDSL4 for General Distribution Installation and Maintenance Practice
NOTE
(Figure
on.
System Indications
In Service
Out-of-Service Maintenance
Currently in startup period
Currently in exiting period
OK, Startup Period COMPLETED
OK, Startup INCOMPLETE (forced in-service)
DSL Loop Sync (T1 alarms ignored)
DSL Loop Sync and absence of T1 alarms
DSL Loop Sync = OK or LOS (LOS shown in
T1 Alarm Status = Alarm or OK
17).
Figure
61223HDSL4L2-5C
22)