View Histogram Screen; Reset Splice Detector; Figure 45. Splice Histogram Screen - ADTRAN HDSL4 Installation And Maintenance Manual

Hdsl4 for general distribution
Hide thumbs Also See for HDSL4:
Table of Contents

Advertisement

HDSL4 for General Distribution Installation and Maintenance Practice

View Histogram Screen

The Splice Histogram Screen
make its result decision.
Circuit ID:HNTSVLALHDSL4
HTUC L2
Splice |
(feet) |
------ |
0100
|
0650
|
1200
|
1750
|
2300
|
2850
|
3400
|
3950
|
4500
|
5055
|
5610
|
6165
|
6720
|
7275
|
7830
|
8385
|
8940
|
9495
|
The definitions of abbreviations shown on this screen are as follows:
• Column1, labeled Splice (feet), represents the distance from the H4TU-C that the anomaly
detector is evaluating.
• Column 2 indicates the respective transceiver that has reported the anomaly. The L1 and
L2 columns represent Loop 1 and Loop 2 of the HDSL4 circuit.
• Column 3 displays the count registered by the H4TU-R, also with Loop 1 and Loop 2
counts.
The remaining columns are for the H4R repeaters (numbered 1, 2, and 3 according to the
number deployed in the circuit. HR1 N is the network side of the first repeater; HR1 C is the
customer side of the repeater, and so forth.
In this example, the distances shown are corresponding to an H4TU-C module since that is
the transceiver that has detected the anomaly. The count of 09 in the 650 feet row under the
H4TU-C, Loop 2, column indicates that an anomaly has been seen 9 times at this distance
from an H4TU-C module. Since 9 is larger than the count detection threshold of 8, this result
is reported to the Splice Results Screen. Since all other columns show 00 for all counts, there
is no reason to Change (
module is evaluating.

Reset Splice Detector

Choose Reset Splice Detector, from the Chronic Circuit Problems screen, to clear all stored
Splice Detection results. A prompt displays to make sure a reset is desired. If
the splice detector re-initializes and starts running again.
61223HDSL4L2-5C
(Figure
45) displays the counters that the splice detector uses to
Press ESC to return to previous menu
<- Press C to Change Distance Ref
H4TUC
H4TUR
HR1 N
L1 L2
L1 L2
L1 L2
-- --
-- --
-- --
00
00
00 00
00 00
00
09
00 00
00 00
00
00
00 00
00 00
00
00
00 00
00 00
00
00
00 00
00 00
00
00
00 00
00 00
00
00
00 00
00 00
00
00
00 00
00 00
00
00
00 00
00 00
00
00
00 00
00 00
00
00
00 00
00 00
00
00
00 00
00 00
00
00
00 00
00 00
00
00
00 00
00 00
00
00
00 00
00 00
00
00
00 00
00 00
00
00
00 00
00 00
00
00
00 00
00 00

Figure 45. Splice Histogram Screen

the view of the distance column to show the distances an H4TU-R
C)
Splice Histogram Screen
HR1 C
HR2 N
HR2 C
L1 L2
L1 L2
L1 L2
-- --
-- --
-- --
00 00
00 00
00 00
00 00
00 00
00 00
00 00
00 00
00 00
00 00
00 00
00 00
00 00
00 00
00 00
00 00
00 00
00 00
Control Port Operation
03/09/05 09:29:45
HR3 N
HR3 C
L1 L2
L1 L2
-- --
-- --
(yes) is chosen
Y
49

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1181413l21223401l21223404l21223406l21223424l21223426l2

Table of Contents