Installation (cont .)
c

Cut Pushbar

Note
If bar does not require cutting, proceed to next step.
a. Measure and mark bar. (Figure 6)
Note
3/4" minimum restriction. (Figure 7)
3/4" min.
b. Fully depress bar and
cut off square on mark.
(Figure 8)
d

Mount Device

Attach bar assembly to door, but do not tighten screws. Assemble rear mounting bracket to push bar (see
nesting arrangement in exploded view in Figure 2). Use rear mounting bracket as a template to spot holes
for mounting screws. Push bar should be level. Drill screw holes and attach rear mounting bracket and
plate to door. Secure front plate screws.
For installation assistance contact Corbin Russwin
1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com
Copyright © 2011, 2019, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole
or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
Figure 7
Cut Off Point
Dogging Hole
Pushbar
Must Be Fully
Depressed
Figure 8
Level
Figure 9
7
Door Width Minus 4-1/2"
Figure 6