Appendix G: Troubleshooting the NJ95
If you encounter problems with the NJ95:
Verify the NJ95 is receiving power by viewing the Power
I
LED (it should be lit). If the Power LED is not lit, make sure:
The other end of the network cable is plugged into a
I
system that provides Power over Ethernet according to
IEEE 802.3af, if using Power over Ethernet.
The Local Power Supply is plugged into the NJ95 and
I
into a working electrical outlet, if using Local power
supply.
Verify the NJ95 is connected to the network properly by
I
viewing the Link LED (it should be lit). If the Link LED is not
lit, make sure the network cable:
Is terminated properly. Refer to the connector
I
manufacturer's instructions for terminating the cable. Be
sure to test the connector and verify it is working.
Has a valid connection to the network.
I
Adheres to proper length and cabling specifications for
I
your network.
Make sure the port on the switch to which the NJ95 is
I
connected is configured as a standard MDI-X port. Make
sure all cables connecting the NJ95 to the patch panel are
straight-through cables (not crossover cables).
Appendix G: Troubleshooting the NJ95
39