3Com 3C17539 Installation Manual page 57

Switch 8800 series
Hide thumbs Also See for 3C17539:
Table of Contents

Advertisement

Figure 36 One Switch 8810 chassis in a cabinet
Switch 8810 14U
(1) Blank filler panel
(3) Backward cabling frame
Guideline: The space marked in Figure 36 must be reserved, and the remaining is
at your disposal.
One Switch 8814 chassis in a cabinet
The components and their height are as follows (from top down):
Blank filler panel (2U)
Cabling frame (2U)
External PoE power supply (or blank filler panel if no external PoE power supply
is installed) (4U)
Blank filler panel (1U)
Back cabling frame (1U)
Switch 8814 chassis (17U)
Blank filler panel (1U)
Cabling frame (2U)
Mounting the Switch in User-Supplied Cabinet
(2) Cabling frame
(4) Reserved for external PoE power supply
57