Technical Data
Technical Data
Category
Maximum Fluid Working Pressure 3500 psi (24.1 MPa, 241 bar)
Fluid Inlets
Fluid Outlets
Fluid Circulation Ports
Maximum Fluid Temperature
Maximum Output (10 weight oil at
ambient temperature) 1:1
Output per Cycle
Stroke Length
Line Voltage Requirement
Amperage Requirement
Heater Power
(A and B heaters total, no hose)
Hydraulic reservoir capacity
Recommended hydraulic fluid
Sound power, per ISO 9614-2
Sound pressure,
1 m from equipment
Weight
Wetted Parts
*Output example: 2.5:1 ratio = 150 cc (B side):60 cc (A side)
2.5:1 output = 150 cc (B side) + 60 cc (A side) = 210 cc per cycle
All other brand names or marks are used for identification purposes and are trademarks of their respective owners.
40
Data
3/4 npsm union in 1 in. npt(f) ball valve
Component A (ISO): #8 (1/2 in.) JIC, with #5 (5/16 in.) JIC adapter
Component B (RES): #10 (5/8 in.) JIC, with #6 (3/8 in.) JIC adapter
1/4 npsm(m), with plastic tubing, 250 psi (1.75 MPa, 17.5 bar) maximum
190°F (88°C)
Model H-VR: 3.0 gpm (11.4 liter/min) (60 Hz)
Variable: 2 oz.- 5 oz. (60 cc - 150 cc) per pump*
Variable: 2 in. - 5 in. (5.08 cm - 12.7 cm)
230V 3 phase units: 195-264 Vac, 50/60 Hz
400V 3 phase units: 338-457 Vac, 50/60 Hz
See Models, page 2.
See Models, page 2.
3.5 gal. (13.6 liters)
Citgo A/W Hydraulic Oil, ISO Grade 46
90.9 dB(A)
84.0 dB(A)
955 lb (433 kg)
Aluminum, stainless steel, zinc-plated carbon steel, brass, carbide, chrome,
fluoroelastomer, PTFE, ultra-high molecular weight polyethylene, chemically
resistant o-rings
313539F