Setup
3.
Electrical requirements
See table 1.
Installing this equipment requires access to parts
which may cause electric shock or other serious injury
if work is not performed properly. Have a qualified
electrician connect power and ground to main power
switch terminals, see step 3. Be sure your installation
complies with all National, State and Local safety and
fire codes.
Table 1: Electrical Requirements (kW/Full Load
Voltage
Part
Model
(phase)
H-VR
230V (3)
256886
H-VR
400V (3)
256887
*
Full load amps with all devices operating at maxi-
mum capabilities. Fuse requirements at various flow
rates, ratios, and mix chamber sizes may be less.
** Total system watts, based on maximum hose length
for each unit, 410 ft (125 m) including whip hose.
18
Amps)
Full
Load
Peak
System
Amps*
Watts**
71
26,600
41
26,600
4.
Connect electrical cord
NOTE:
Power cord is not suppled. See table 2.
Table 2: Power Cord Requirements
Part
Model
H-VR
256886
H-VR
256887
a. 230V, 3 phase: Using 5/32 or 4 mm hex allen
wrench, connect three power leads to L1, L2,
and L3. Connect green to ground (GND).
L1
L2
b. 400V, 3 phase: Using 5/32 or 4 mm hex allen
wrench, connect three power leads to L1, L2,
and L3. Connect neutral to N. Connect green to
ground (GND).
L1
L2
L3
NOTE:
The motor must rotate counter-clockwise when viewed
from shaft end. To reverse rotation, disconnect power
and reverse power leads L1 and L2.
Cord Specification
2
AWG (mm
)
4 (21.2), 3 wire + ground
8 (8.4), 4 wire + ground
GND
ti2515b
GND
ti3248b
313539F