Motor Controls And Indicators; Motor On/Off Key/Led; Park Key/Led; Psi/Bar Keys/Leds - Graco REACTOR H-VR Operation

Hydraulic variable ratio, heated, plural component proportioner. for spraying polyurethane foam and polyurea coatings
Hide thumbs Also See for REACTOR H-VR:
Table of Contents

Advertisement

Motor Controls and Indicators

Arrow Keys
Motor ON/OFF Key
PARK Key
Pressure Key
Cycle Count Key
F
. 6. Motor Controls and Indicators
IG

Motor ON/OFF Key/LED

Press
to turn motor ON and OFF. Also clears
some motor control diagnostic codes, see page 35.

PARK Key/LED

Press
at end of day to cycle component A pump
to home position, submerging displacement rod. Trigger
gun until pump stops. Once parked, motor will automati-
cally shut off.

PSI/BAR Keys/LEDs

PSI
BAR
Press
or
to change pressure scale.
313539F
ON / OFF
PARK
PSI
BAR

Pressure Key/LED

Press
to display fluid pressure.
NOTE:
If pressures are imbalanced, display shows higher of
two pressures.
Motor Controls and Indicators
Pressure/Cycle Display
PSI/BAR Keys
15

Advertisement