Advanced Ent ry Calibrat ion ( cont inued)
St e p
Act ion
Use t he UP and DOWN Arrow
but t ons t o set t he Gain Num ber t o
00.
F
Record t he sensor reading as a
Label Value for Gain Num ber 00 in
a t able ( 32 rows by four colum ns,
wit h headings sim ilar t o t hose
shown below .)
Gain Num ber
00
01
02
...
31
St e p
Act ion
Use t he UP and DOWN Arrow
but t ons t o incr em ent t he Gain
Num ber by one and t hen Record
G
t he Label Value.
Repeat t his pr ocess for each Gain
Num ber .
Gain Num ber
00
01
02
...
31
Ch a pt e r 3 - Pr int e r Ope r a t ion
D ispla y e d M e ssa ge
TRAN SENSOR GAI N
00
( 0 - 31)
Sam ple Calibrat ion Table
Label Value
TOF Value
252
D ispla y e d M e ssa ge
TRAN SENSOR GAI N
01
( 0 - 31)
Sam ple Calibrat ion Table
Label Value
TOF Value
252
250
248
...
09
Com m e n t
This is t he Label Value for a gain
set t ing of 00.
Difference Value
Com m e n t
This is t he Label Value for a gain
set t ing of 01.
Difference Value
2 9