Bosch Rexroth VT-VSPD Series Installation And Operation Manual page 34

Digital valve amplifier
Table of Contents

Advertisement

34/48
Bosch Rexroth AG | Hydraulics
4 Operating the VSPD
Level 1
Level 2
Faults
Press "ENTER + ESC"
Voltage
to go to the configura-
(b14/b16)
tion menu
Current
(b22/b24)
Ramp+
(b6/b8)
Ramp-
(b18/b20)
short circ sol a+b
cable break sol a+b
Hyquip Limited New Brunswick Street Horwich Bolton Lancashire BL6 7JB UK
Company Registered in England No: 4167649 VAT Registration No: 732 5692 25 BS EN ISO 9001:2008 No: LRQ 0964389
+44 (0)1204 699 959
enquiries@hyquip.co.uk
Level 3
Type
Debounce
Type
Debounce
Type
Debounce
Type
Debounce
Type
Debounce
Type
Debounce
Fig. 17 Menu tree „Faults"
www.hyquip.co.uk/web/index
Installation and operation | RE 30523-B/09.13
Level 4
Level 5
Off
Stop
Flag
[+0.01~+60.00]
Off
Stop
Flag
[+0.01~+60.00]
Off
Stop
Flag
[+0.01~+60.00]
Off
Stop
Flag
[+0.01~+60.00]
Stop
[+0.01~+0.25]
Off
Stop
Flag
[+0.01~+0.25]