To reduce the risk of electric shock, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so. 2014.01 | V1.1 | LBB193x/x0 Installation and Operation manual Bosch Security Systems B.V.
The equipment or the property can be seriously damaged, or persons can be severely injured if the alert is not observed. Danger! Not observing the alert can lead to severe injuries or death. Bosch Security Systems B.V. Installation and Operation manual 2014.01 | V1.1 | LBB193x/x0...
For information on getting permission for reprints and excerpts, contact Bosch Security Systems B.V.. The content and illustrations are subject to change without prior notice.
The amplifiers have overload and short‑circuit protection. A temperature controlled fan and overheat protection gives high reliability. Battery operation with automatic switchover from the mains supply is available. Bosch Security Systems B.V. Installation and Operation manual 2014.01 | V1.1 | LBB193x/x0...
- Ensure sufficient ventilation and enough room, about 10cm / 4” behind the unit for cables and connections. - Use the included Bosch 19” mounting brackets (LBC 1901/00) x2. - Remove the tabletop feet from the bottom of the unit.
This selection does not affect the output voltage of the loudspeaker direct outputs. F701 100V F702 Figure 5.4: Internal fuse setting LBB 1930/20, LBB 1935/20, LBB 1938/x0 See also – Rear panel connectors and switches, page 9 Bosch Security Systems B.V. Installation and Operation manual 2014.01 | V1.1 | LBB193x/x0...
Wa rnin P owe T his app arat r : 50V us mus T 1.0A t be L 250 eart hed Figure 6.2: Line input and loop‑through 2014.01 | V1.1 | LBB193x/x0 Installation and Operation manual Bosch Security Systems B.V.
(70V). Connect the loudspeakers in parallel and check the loudspeaker polarity for in- phase connection. The summed loudspeaker power should not exceed the rated amplifier power. Bosch Security Systems B.V. Installation and Operation manual 2014.01 | V1.1 | LBB193x/x0...
D ire ct O utput 100V Priority Controlled Output 24V DCIn 100V 100V Priority Only No Priority Priority Only No Priority Figure 6.4: Priority input and control terminals 2014.01 | V1.1 | LBB193x/x0 Installation and Operation manual Bosch Security Systems B.V.
Loudspeakers connected to the No Priority output will receive all audio signals, such as music, but no signals with priority, like calls. Power Use the mains lead to connect the amplifier to the power supply. Figure 6.5: Mains lead Bosch Security Systems B.V. Installation and Operation manual 2014.01 | V1.1 | LBB193x/x0...
(falls below the threshold of -20%), and the back‑up power supply takes over, the fault relay moves to the NOK position. A mains fault indication shows on the front panel and a fault state is given by the mains fault relay. 2014.01 | V1.1 | LBB193x/x0 Installation and Operation manual Bosch Security Systems B.V.
Input fault relay switches over if the power stage is switched “OFF” by the overheat protection circuit. The Battery operation indicator (3) lights up if the mains power supply is failing and the back‑up battery is in use. Bosch Security Systems B.V. Installation and Operation manual 2014.01 | V1.1 | LBB193x/x0...
100V 1 00V 100V 1 00V Input Input Priority Only No Priority Input Input Priority Only No Priority Figure 8.3: LBB1925/10 and power amplifier control terminals example 2014.01 | V1.1 | LBB193x/x0 Installation and Operation manual Bosch Security Systems B.V.
The ground (Protective Earth) connection of the system components. Warning! Dangerous mains voltages are present inside the units. Disconnect the main power supply before doing any maintenance tasks. Bosch Security Systems B.V. Installation and Operation manual 2014.01 | V1.1 | LBB193x/x0...
44 V / 240 W LBB 1938/x0 62 V / 480 W Power reduction@24 V battery operations Reference rated power -1 dB (LBB 1935/20) -2 dB (LBB 1930/20 LBB 1938/x0) Bosch Security Systems B.V. Installation and Operation manual 2014.01 | V1.1 | LBB193x/x0...
- 3 dB Watt - 6 dB 244** 508** Watt Watt Idle Watt Backup power (24VDC) Full power - 3 dB - 6 dB 18** Idle Full power Watt 2014.01 | V1.1 | LBB193x/x0 Installation and Operation manual Bosch Security Systems B.V.
Page 23
Watt Idle Watt * Output limited to -3dB ** Corresponds to pink noise and voice on full power *** Output limited for sine wave signal to -3dB Bosch Security Systems B.V. Installation and Operation manual 2014.01 | V1.1 | LBB193x/x0...
Relative humidity < 95% EMC emission According to EN55103‑1 EMC immunity According to EN55103‑2 Acoustic noise level of fan < 45 dB SPL @ 1m at maximum speed 2014.01 | V1.1 | LBB193x/x0 Installation and Operation manual Bosch Security Systems B.V.