Error Code
An outlet solenoid error has been detected. Try powering off the product for 30
45
seconds or resetting in the Mira Showers app.
No (or very low) flow has been detected by the product. This can be caused by the
inlet water supply being isolated or restricted. Check isolators are open and that
50
the filters or handset and hose are not blocked. Resolve the issue then reset error
by powering off the product for 30 seconds or resetting in the Mira Showers app.
Refer to diagnosis section 4b.
Flow has been detected when the product should be off. Try powering off the product
53
for 30 seconds or resetting in the Mira Showers app. Refer to diagnosis section 4c.
Unusually high flow has been detected. Try powering off the product for 30 seconds
54
or resetting in the Mira Showers app.
User Interface stuck button detected. Check that your user interface is free to move
55
and then power off the product for 30 seconds or reset the product in the Mira
Showers app. If the error re-appears please contact Mira customer services team.
User Interface has lost communications with the valve. Check the connection cable
is intact and plugged into the valve securely. Power off the product for 30 seconds
66
or reset the product in the Mira Showers app. If the error re-appears please contact
Mira customer services team.
110
Hot Inlet thermistor not detected - contact Mira customer services team.
A hot inlet water temperature above the specification has been detected. This
can cause dangerous temperature spikes or product damage. Resolve the issue
112
then reset error by powering off the product for 30 seconds or resetting in the Mira
Showers app.
Diagnosis stage 2 (Valve status check):
If you do not have an error code, or if the controller is
not functional you should then check the status indicator
light on the product.
Power Indicator Status
Blue
Red
Flashing Red/Blue
Off
Description and remedial action
Product should be functional. If your product is still exhibiting problems
continue to Diagnosis stage 4.
Product has an error. Follow Diagnosis stage 1 or continue to Diagnosis
stage 4.
(Pumped Product Only) Product is in priming sequence. Follow the
commissioning sequence in "Commissioning Section".
Product is not receiving power. See Diagnosis stage 3.
Description