Mira Digital Mixing Valve Pumped/Gravity (not suitable for mains pressure systems)
Note: The pump in this product is not suitable for dry running. It is essential you
follow the commissioning sequence detail in this guide.
Pressures
Thermostatic Standard
Maximum Static Pressure
Maximum Maintained Pressure
Minimum Maintained Pressure
Supply Pressure Differential
Temperatures
Maximum Temperature (setting range)
Minimum Temperature
Hot Water Range - Supply
Cold Water Range - Supply
Temperature Stability at Valve Outlet
Ambient Temperature
Maximum Relative Humidity
Flow Rates
Nominal Flow Rate*
Electrical Rating
Supply Voltage
Maximum Load
Output Supply Voltage to Valve
Note: Valves operating outside of the manufacturers recommended conditions of
use cannot be guaranteed to operate as TMV2 Type 2 valves.
User Control
Electrical Supply
Ingress Protection
Maximum Ambient Temperature
TMV 2 - HP (BS EN 1111 Type 2)
100 kPa (1 bar) 10m head
100 kPa (1 bar) 10m head
1 kPa (0.01 bar) 0.10m
Nominally equal
35°C - 48°C (Factory Preset 45°C)
Thermostatic control down to 30°C
Full Cold also selectable
55°C - 65°C
1°C - 20°C
± 1°C at recommended supply conditions
1°C - 50°C
95% non-condensing at 30°C
Valve capable of up to 12 l/min @ 0.1 bar
100V - 240V AC 50/60Hz
80W
12V DC & 24V DC
12V DC SELV 2W Max
IPX5
40°C