How To Adjust The Operating Temperature Of S1 Vivaldi Ii - Laspaziale S1 Vivaldi Instruction Manual For The Installer

Table of Contents

Advertisement

To calibrate the delivery group temperature to a one degree (centigrade) step adjustment:
Switch off the appliance by pressing the ON / OFF button, the green led (22) will go from fixed to flashing
(machine on standby mode).
Press and hold down the two coffees button (25) for about 3 seconds; the leds 17 and 18 will switch
on to show that the calibration phase with 1°C step adjustment has been entered.
Every time that the boiler button (26) is pressed, the leds 19, 20, 21 will switch on in sequence to show
a one degree centigrade increase from the set temperature, while each time that the one coffee button
(24) is pressed, the leds 16,15,14 will switch on in sequence, with each led showing a decrease of one
degree centigrade compared to the set temperature.
For example, if the set temperature is 105°C and the leds 19 and 20 switch on, the new temperature
will be 105+2 = 107°C.
The operating temperature of the machine is changed exclusively for the purpose of improving the result
in the cup, according to the coffee blend used.
2.3

HOW TO ADJUST THE OPERATING TEMPERATURE OF S1 VIVALDI II

1. While the appliance is operating, press and hold down the ON//OFF button (27) for about 3 seconds;
the line control light (22) and the set temperature led will flash. For example, if the set temperature is
95 °C, the led (18) will flash.
LIGHT No. 13
TEMP.
2. To change the operating temperature, press and hold down the hot water delivery button (23); the
temperature will increase by 1°C each time the button is pressed (and the relevant led will switch on
and flash). At the maximum temperature of 97°C (led 20) the selection will start again from the minimum
temperature of 91°C (led 14) -cyclical function- .
3. Once the required temperature has been selected, press the ON/OFF (27) button to confirm the setting;
the appliance will return to normal operation.
To set a delivery group temperature to less than 91°C or more than 97°C proceed as follows:
N. B.
Access to this programming function is enabled only when the set temperature for the delivery
group is set to the minimum (91°C) or more than 97°C.
Switch off the appliance by pressing the ON/OFF button (27); the green led (22) will go from fixed to
flashing (machine on standby).
Press and hold down the two coffees button (25) for about 3 seconds; the leds 17 and 18 will switch on
to indicate that you have entered into the programming phase for decrease of the minimum temperature
and increase of the maximum temperature.
Every time the steam delivery button (26) is pressed, the leds 19, 20 and 21 will switch on in sequence to
show a one degree centigrade increase compared to the set temperature, if starting from a temperature
setting of 97°; while each time that the one coffee button (24) is pressed, the leds 16, 15 and 14 will
switch on in sequence with each led showing the decrease of one degree centigrade compared to the
set temperature, if starting from a temperature setting of 91°C. For example, if the set temperature is
97°C and the leds 19 and 20 switch on, the new set temperature will be 97 + 2 = 99°C.
The operating temperature of the machine is changed exclusively for the purpose of improving the result in
the cup, according to the coffee blend used.
8
LSI 005 -UK- REV. 04
14
15
16
91
92
93
INSTRUCTIONS MANUAL FOR THE INSTALLER
17
18
19
94
95
96
20
21
22
97
°C