Selecting The Unguator® Jar Size; Condition Of The Ingredients For Any Formula; Tab. 5: Minimum Values For Mixing Time At 2150 Rpm In Min:s; Tab. 6: Minimum Values For Mixing Time At 1650 Rpm In Min:s - Gako UNGUATOR Q Operatng Instructons And Producton Recomendatons

Table of Contents

Advertisement

minimum mixing time for any given formulation may vary.
The following time values for each rpm serves as benchmark, which should be adjusted
after each modification of rpm.
Type of formulation
Suspension
Soft-in-soft
Emulsion
Type of formulation
Suspension
Soft in soft
Emulsion
6.6 Selecting the UNGUATOR® Jar Size
The maximum rpm for jar sizes 100ml and greater is restricted. This is a safety feature to
optimize the power exposure for all material, jars, and mixing blades particularly when
using larger UNGUATOR® jars.

6.7 Condition of the ingredients for any formula

Powder
Generally powders should be used as microfine substances.
In order to ensure better wetting of powders in aqueous formulations, micronized
substances should be added only after any liquid constituents.
For a solids content less than 2%, we recommend applying a pregrinding process together
with approx. 30% of the ointment base (see paragraph 6.3.4 - pregrinding program).
27
Size of the UNGUATOR® Jar
15-30ml
02:00
01:40
02:00

Tab. 5: Minimum values for mixing time at 2150 rpm in min:s

Size of the UNGUATOR® Jar
15-30ml
03:00
02:30
03:00
Tab. 6.: Minimum values for mixing time at 1650 rpm in min:s
50-100ml
200-300ml
02:30
02:10
02:20
50-100ml
200-300ml
03:50
03:20
03:50
500ml
04:30
06:10
04:00
05:10
04:10
05:30
500ml
06:45
09:30
06:10
07:50
06:30
08:30