Advertisement

TSI MEDIA 2I - 120VAC
User Manual V7.1
BEYOND THE INVERTER
THE NEW GENERATION OF POWER CONVERTERS
DUAL INPUT INVERTER
The Commercial Power as default source
AC BACKUP IN A DC ENVIRONMENT
Leverage your existing DC infrastructure
ONE STOP SHOP
wide output power range
HARSHEST AC INPUT CONDITIONS
Without compromising the quality of the AC output
Important Safety Instructions and Save these Instructions
Copyright © 2013. Construction electroniques & telecommunications S.A.
All rights reserved. The contents in document are subject to change without notice.
The products presented are protected by several international patents and trademarks.
Address: CE+T S.a, Rue du Charbonnage 12, B 4020 Wandre, Belgium
www.cet-power.com - info@cet-power.com
www.cet-power.com

Advertisement

Table of Contents
loading

Summary of Contents for CE+T Power TSI MEDIA 2I

  • Page 1 TSI MEDIA 2I - 120VAC User Manual V7.1 BEYOND THE INVERTER THE NEW GENERATION OF POWER CONVERTERS DUAL INPUT INVERTER The Commercial Power as default source AC BACKUP IN A DC ENVIRONMENT Leverage your existing DC infrastructure ONE STOP SHOP...
  • Page 2: Table Of Contents

    8. Media 2I Shelves Installation ............................. 8.1 Unpacking the System ............................8.2 Mechanical Installation ............................. 8.2.1 System Dimensions ..........................8.2.2 Fixing..............................8.2.3 Mounting Kit ............................8.2.4 Pre requisites............................8.2.5 Terminations ............................– TSI Media 2I – User manual – v7.1...
  • Page 3 14.2 Defective modules ............................14.2.1 Replacing modules ..........................14.2.2 Return defective T2S interface ......................14.2.3 Return defective shelf .......................... 14.2.4 Return defective modules ........................15. Service ..................................16. Maintenance Task ..............................– TSI Media 2I – User manual – v7.1...
  • Page 4 Release Note: Release date Modified page Version Modifications (DD/MM/YYYY) number 03/02/2010 First release of the Manual. 30/01/2015 New Layout. – TSI Media 2I – User manual – v7.1...
  • Page 5: Ce+T At A Glance

    CE+T at a glance 1. CE+T at a glance CE+T Power designs, manufactures and markets a range of products for industrial operators with mission critical applications, who are not satisfied with existing AC backup systems performances, and related maintenance costs.
  • Page 6: Abbreviations

    Transmission Control Protocol/Internet Protocol Universal Serial Bus Protective Earth (also called Main Protective Conductor) Neutral Printed Circuit Board True Redundant Structure Miniature Circuit Breaker MCCB Molded Case Circuit Breaker Circuit Breaker – TSI Media 2I – User manual – v7.1...
  • Page 7: Safety Instructions

    When handling the system/units pay attention to sharp edges. * These instructions are valid for most CE+T Products/Systems. Some points might however not be valid for the product described in this manual – TSI Media 2I – User manual – v7.1...
  • Page 8: Installation

    Some areas are more susceptible to be hit by electrical strikes, especially when altitude increases. Good earthing is also crucial for surge arrestors to work properly. CE+T decline any liability in regard to damaged caused to equipments not correctly or not sufficiently protected. – TSI Media 2I – User manual – v7.1...
  • Page 9: Other

    If the equipment is dismantled, to dispose of the products it consists of, you must stick to the local regulations in force in the country of destination and in any case avoid causing any kind of pollution. To download the latest documentation and software, please visit our website at www.cet-power.com. – TSI Media 2I – User manual – v7.1...
  • Page 10: Tsi Technology

    1 | Information and data given in this chapter intend to for an overview on the technology. Detailed features and parameters for each individual module type of the range may differ and should be referred in the dedicated data sheet. – TSI Media 2I – User manual – v7.1...
  • Page 11: On-Line Mode

    Setting for Walk -in -Mode and Mix Mode can be made through the T2S supervisor configuration file. See section10, page 30 for more information on T2S supervisor. – TSI Media 2I – User manual – v7.1...
  • Page 12: Design And Description

    Utilizing both a 48Vdc and a 120/240V AC input, these high density systems range from 1500VA to 3000VA and are mountable in a standard 19 inch cabinet or either a 19 inch or 23 inch open relay rack. Media 2I System - Block Diagram – TSI Media 2I – User manual – v7.1...
  • Page 13: System Design

    Media 2I is an application modular inverter system specifically designed for clean and temperature controlled environments. Telecom grade design. „ „ „ „ Based on MEDIA 48VDC-120VAC TSI module. „ „ Fully modular. „ „ Support redundant configurations. Support EPC mode. „ „ Rear View – TSI Media 2I – User manual – v7.1...
  • Page 14: System Technical Description

    5.8 EMC Standards EN 5502 „ „ FCC 47 CFR Part 15 „ „ – TSI Media 2I – User manual – v7.1...
  • Page 15: Building Blocks

    MEDIA 2I Inverter Systems are available in two base configurations, as follows: „ „ 1. Single Phase Output with and Without Redundancy with optional AC output receptacles. „ „ 2. Split Phase Output without Redundancy with optional AC output receptacles. – TSI Media 2I – User manual – v7.1...
  • Page 16: Accessories

    „ 3 outgoing alarms contacts. „ „ 2 digital inputs. „ „ MOD bus. CAN bus (optional). „ „ Alarm monitoring. „ „ „ „ Record the latest 200 events. FIFO. – TSI Media 2I – User manual – v7.1...
  • Page 17: Media 2I Shelves Installation

    19” or 23” equipment racks. Verify the mounting hardware provided is as required for your application prior to installation. Verify sufficient space is allowed for proper air circulation. „ „ Verify the following hardware is on hand; „ „ – TSI Media 2I – User manual – v7.1...
  • Page 18: Mounting Kit

    8.2.3 Mounting Kit Step 1: Mount brackets to side of shelf with two supplied screws (Mid Mount shown) Step 2: Mount shelf to uprights of relay rack or cabinet – TSI Media 2I – User manual – v7.1...
  • Page 19: Pre Requisites

    „ „ stating message as “ISOLATE UNINTERRUPTIBLE POWER SUPPLY (UPS) BEFORE WORKING ON THIS CIRCUIT”. 8.2.5 Terminations Rear Side of Media 2I system terminations are clearly marked in the following figure – TSI Media 2I – User manual – v7.1...
  • Page 20: Electrical Installation

    20A 2-Pole UL489 240V - #12AWG, 90°C Copper Wire *Actual size to be determined by, and in compliance with, local utility codes. TSI shelf is supplied with screw terminal: Neutral, Line and Ground. – TSI Media 2I – User manual – v7.1...
  • Page 21: Connecting Dc Input Power

    Max wire insulation diameter** in / mm 0.437 / 11.10 * UL Rated for 65°C largest wire or cable size ** Actual size to be determined by, and in compliance with, local utility codes – TSI Media 2I – User manual – v7.1...
  • Page 22: Grounding The System

    WARNING: Low impedance grounding is mandatory for personnel safety, critical for the proper operation of the system and must be in place and connected to the system before the supply cables are connected. – TSI Media 2I – User manual – v7.1...
  • Page 23: Remote Monitoring And Control

    Access to locking latch to remove T2S from Inverter shelf Note: All alarms are qualified in Minor alarm except those configurable by T2S. These configurable alarms are identified by the ID601 to 900. Refer to list of factory settings. – TSI Media 2I – User manual – v7.1...
  • Page 24 Reverse procedure to remove wire. * For this connector, the allowable wire gauge range is #20AWG to #28AWG. The actual size to be determined by, and in compliance with, local utility codes – TSI Media 2I – User manual – v7.1...
  • Page 25 State #3 should be implemented by default. Changing status of these inputs (State #3 State #2 State #3) forces the TSI modules to start running without T2S. Common Note: Mating connectors supplied as part of shelf assembly. Maximum wire gauge is #22AWG. – TSI Media 2I – User manual – v7.1...
  • Page 26: Wiring - Receptacle

    Four NEMA 15R Receptacles in PDU Extension, Single phase AC out connections Two NEMA 15R, one twist lock Receptacles in PDU Extension, Single and Dual phase AC out connections Two twist lock Receptacles in PDU Extension, Dual phase AC out connections – TSI Media 2I – User manual – v7.1...
  • Page 27: Ac Output Wiring - Hardwired

    This parameter can be adjusted in T2S, however, if the parameter is set at a value > 5 seconds, an external protection must be provided in order that the short circuit protection operates within 5 seconds The default value is set at 60 seconds. – TSI Media 2I – User manual – v7.1...
  • Page 28: Internal Bus (Tsi Bus 6 Pin / Tsi Bus 8 Pin)

    Once the shelf has been fully wired, the Inverter Modules can be installed. Before installation of any of the modules, verify all upstream and downstream circuit breakers are in the OFF (open) position Refer Section 11.1.2, page 32 for module inserting procedure. – TSI Media 2I – User manual – v7.1...
  • Page 29: Human-Machine Interface

    40 to 80 to 100% = <5% 100% Output Power (redundancy not counted) overload × × × × × Status output power LED × Behaviour (B = blinking – P permanent ) – TSI Media 2I – User manual – v7.1...
  • Page 30: T2S

    Read T2S manual for detailed setup. 10.1 Communication Setting „ „ Bits per second 115200 Data bits „ „ Parity None „ „ Stop bits „ „ „ „ Flow control None – TSI Media 2I – User manual – v7.1...
  • Page 31: Menu Access

    1 > Force refresh of configuration texts and constants 2 > Force refresh of events description texts 4 > Security Access 0 > Return to index 1 > Enable Password protection – TSI Media 2I – User manual – v7.1...
  • Page 32: Inserting/Removing/Replacing Modules

    „ A) Slide the module in B) Push firmly till the connection is C) Close the cover and latch the module properly engaged in place if too hard redo step B – TSI Media 2I – User manual – v7.1...
  • Page 33: T2S

    Replace front, make sure that the front latch properly. Plug in. „ „ Check fan for operation. „ „ Access T2S and reset the fan run time alarm from within the action menu. „ „ – TSI Media 2I – User manual – v7.1...
  • Page 34: Final Check

    Cover empty inverter positions with blanks. „ „ Make sure that the Remote ON/OFF is appropriately wired according to local regulations. „ „ „ „ Make sure that the point of AC supply meets local regulations. – TSI Media 2I – User manual – v7.1...
  • Page 35: Commissioning

    Installation and commissioning must be done and conducted by trained people fully authorized to act on installation. It is prohibited to perform any isolation test without instruction from manufacturer. Equipments are not covered by warranty if procedures are not respected. – TSI Media 2I – User manual – v7.1...
  • Page 36: Check List

    Switch OFF AC input (commercial power failure) and check the alarm according to the configuration Switch OFF DC input (DC power failure) and check that the alarm according to the configuration Check the different digital input according to the configuration (when used) – TSI Media 2I – User manual – v7.1...
  • Page 37: Trouble Shooting And Defective Situations Fixing

    Check that the RJ45 cable is connected between T2S shelf and CanDis shelf No value on TCP/IP: Check that the RJ45 cable is connected between T2S shelf and CanDis shelf Wait approx 2 minutes to allow the system to collect serial data. – TSI Media 2I – User manual – v7.1...
  • Page 38: Defective Modules

    „ „ „ Be aware that products shipped back to CE+T Power without being registered first will not be treated with high priority! „ „ Information on failure occurrence as well as module status given through Menu 2-1 shall be attached to defective unit return package or recorded in RMA.
  • Page 39: Service

    CE+T will redirect your call to your vendor if he has such SLA in place. (**) Valid in USA and Canada only. (***) Messages that are not Major Incident or Emergency will be served at the next scheduled working day. – TSI Media 2I – User manual – v7.1...
  • Page 40: Maintenance Task

    „ „ * It is not recommended because when you perform a By-pass procedure, generally there is no back up on AC input line, and the load shutdown if mains disappear. – TSI Media 2I – User manual – v7.1...

Table of Contents