1
3
1. Fluid-tank filler cap
2. Suction strainer
Checking the Hydraulic Fluid
Overheat Warning System
Service Interval: Every 500 hours
1. Temperature switch
1. Turn the ignition key to the ignition on position I.
2. Disconnect the red/yellow wire terminal from the
hydraulic tank temperature switch.
3. Touch the metal terminal of the wire onto a suitable
ground point, ensuring that the metal surfaces make
good contact.
The horn sounds and the hydraulic fluid temperature warning
light illuminates to confirm correct operation. If necessary,
make repairs before operating the mower.
2
G014452
Figure 56
3. Filler strainer
1
2
g022285
Figure 57
2. Hydraulic-fluid tank
Checking the Hydraulic Lines
and Hoses
Daily, check hydraulic lines and hoses for leaks, kinked
lines, loose mounting supports, wear, loose fittings, weather
deterioration, and chemical deterioration. Make all necessary
repairs before operating.
g014452
g022285
46