Moving or relocating the FAStT700 Storage Server

Use the following procedure to remove all component CRUs before moving or
relocating the FAStT700 Storage Server.
1. Prepare the FAStT700 Storage Server for shutdown. Refer to "Turning off the
power" on page 19.
2. Label the host Fibre Channel and interface cables and disconnect them.
Attention:
Handle and install fiber-optic cables properly to avoid degraded
performance or loss of communications with devices. When working with
fiber-optic cables, do not pinch them, step on them, or locate them in aisles or
walkways. Do not bend the cables to a radius of less than 38 mm (1.5 in.).
3. Disconnect all remaining cables from the FAStT700 Storage Server and label
them so that you can correctly reconnect them later.
Attention:
When you handle static-sensitive devices, take precautions to
avoid damage from static electricity. For details about handling static-sensitive
devices, see "Handling static-sensitive devices" on page 35.
4. Remove all CRUs from the FAStT700 Storage Server. For information about
removing and replacing CRUs, see "Chapter 3. Replacing FAStT700 Storage
Server components" on page 35.
5. Remove the two screws from the inside rear of the FAStT700 Storage Server;
then, remove the two screws from the inside front of the FAStT700 Storage
Server. Save the screws for later. For detailed information, see the Rack
Mounting Instructions that come with the storage server.
Attention:
Do not remove the black hex head screws. These secure the rails
that support your FAStT700 Storage Server.
Statement 4:
≥ 18 kg (39.7 lb)
CAUTION:
Use safe practices when lifting.
6. Slide the FAStT700 Storage Server out of the rack cabinet and set it on a
level, dry surface.
7. Do one of the following:
v If you are shipping the FAStT700 Storage Server to another location,
replace all CRUs in the FAStT700 Storage Server. Carefully pack the unit in
its original shipping container. You are finished with this procedure.
v If you are moving the FAStT700 Storage Server to another rack cabinet,
remove the support rails and power cords from the old rack cabinet and
install them in the new one.
≥ 32 kg (70.5 lb)
Chapter 2. Operating the FAStT700 Storage Server
≥ 55 kg (121.2 lb)
33