Servicing notes

Consider the following when servicing the fan and communications module:
v The fan and communications module contains two Ethernet connections used for
v You can hot swap the fan and communications module as long as you complete
v It is unlikely that the storage server fan and the fan and communications module
v If you replace the fan and communications module and still experience problems,

Replacing a failed fan and communications module

When instructed by the storage-management or diagnostic software, replace the fan
and communications module.
Attention:
operate the FAStT700 Storage Server without adequate ventilation to the power
supplies and mini hubs. If it will take longer than 15 minutes to replace the fan and
communications module, you must shut down the FAStT700 Storage Server to
prevent it from overheating. The time limit applies only to the total time that the fan
and communications module is out of the chassis. The time begins when you
remove the failed module and ends when you install the new one. This does not
include the time it takes you to perform this entire procedure (for example, checking
the indicator lights).
1. Disconnect all Ethernet interface cables from the failed fan and communications
direct network-management.
the exchange within 15 minutes from when you remove the failed unit until you
install the new one.
cooling system will fail simultaneously. Such a failure will cause one or both
power supplies to overheat. In these circumstances, the amber power supply
indicator light on the bezel is lit and the overheated power supply automatically
shuts down (the green power indicator light on the power supply turns off). Once
the ambient air temperature cools below 70° C (158 F), the power supply
automatically turns on. Replace the failed fan and communications module; then,
check the power supply indicator lights (fault indicator light on the front and
power indicator light on the back). If the power supply fault indicator light remains
on, replace the power supply. For more information about indicator lights, see
"Fan and communications module indicator light" on page 26 and the Figure 27
on page 27.
the FAStT700 Storage Server might have defective components or connections.
Check the storage-management software for indications of other component
failures.
To prevent damage to the FAStT700 Storage Server circuitry, do not
module. The locations of the ports are shown in the following figure.
Captive screws
2 Gb/s
2 Gb/s
2 Gb/s
2 Gb/s
1 Gb/s
1 Gb/s
1 Gb/s
1 Gb/s
!
!
!
!
OUT
OUT
OUT
OUT
IN
IN
IN
IN
Controller B Ethernet port
Controller A Ethernet port
2 Gb/s
2 Gb/s
2 Gb/s
2 Gb/s
1 Gb/s
1 Gb/s
1 Gb/s
1 Gb/s
!
!
!
!
OUT
OUT
OUT
OUT
IN
IN
IN
IN
Fan and communications
indicator light
Chapter 3. Replacing FAStT700 Storage Server components
47