3.26 SP525A

This model protects a twinax device for System 3X
or AS/400.
1. Disconnect the data cable from the device.
2. Connect the surge protector to the device
directly. If the device has a female
connector, then you may connect a short
piece of twinax between the device and the
protector. The cable should not be more
than one foot (0.3 m) long, because the
protector needs to be grounded to the device
chassis if metal, or to the electrical outlet
ground. Longer cable will reduce the
effectiveness of the protector.
3. Attach the ground wire to the device chassis
if metal, or to the device's electrical ground.
If you do not properly install the protector, you could
damage the device. We also recommend AC power
protection.
4. Attach the data cable to the protector.