IN-LINE SURGE PROTECTORS

3.24 SP523A-R2

This model protects Token Ring devices.
1. Remove data cable from the device you wish
to protect.
2. Attach a short (1 foot or less) piece of cable
from the device to the terminal strip on the
protector.
3. Attach the protector ground wire to the
device chassis if metal, or to the device
electrical outlet ground.
If you do not connect the ground properly, you could
damage your equipment.
4. Attach the data cable to the other terminal
strip.