Example - Secvest - Abus wAppLoxx Pro Control Installation And Operating Instructions Manual

Hide thumbs Also See for wAppLoxx Pro Control:
Table of Contents

Advertisement

Only the Arm Input is connected to the Arm Output of the alarm panel. This involves using the
alarm panel to lock the wAppLoxx Pro Control in its "armed" position until the alarm panel
unlocks it again. It is not possible to use the wAppLoxx Pro Control to "disarm" the system
here. You can only actuate the connected wAppLoxx Cylinders when the alarm system is
unarmed.
4. No alarm panel (locking function via wAppLoxx Pro Control)
Only the Arm Output of the wAppLoxx Pro Control is configured, although it is not connected.
This makes it possible to lock the cylinders with an Arm command until a valid Arm/Disarm
medium is presented.
10.2 Example – Secvest
On the Secvest Control, Input 1 is used for arming preparation, Input 2 for arming
acknowledgement and Input 3 in case of alarm. Output 1 of the wAppLoxx Control controls the
zone input 1 on the Secvest for arming, the output 2 of the Control controls zone 2 of the
Secvest for tamper triggering.