Air Exhaust
Exhaust Ventilation
Air
Air
Exhaust
If pumping toxic fluids, you must vent the exhaust
away from people, animals, food handling areas,
and all sources of ignition. Follow all applicable
codes.
NOTE:
NOTE: Do not restrict the air exhaust port. Excessive
NOTE:
exhaust restriction can cause erratic pump operation.
J
Air inlet port (not visible)
K
Exhaust port
S
Grounded air exhaust hose
334794B
Springer Pumps, LLC
Telford, PA 18969
Ventilation
Ventilation
Tel: 866-777-6060 / Int'l: 215-949-2900
Fax: 866-777-6383 / Int'l: 215-721-1296
To provide
To
To
provide a a a remote
provide
remote exhaust:
remote
exhaust:
exhaust:
1. Use Kit 17F612 (NPT) or 17F613 (BSPT), sold
separately.
2. Remove the muffler (U) from the pump air
exhaust port (K).
3. Install the adaptor from the kit.
4. Install a grounded air exhaust hose (S). If a hose
longer than 10 ft. (3 m) is required, use a larger
diameter hose. Avoid sharp bends or kinks in
the hose.
5. Place a container (T) at the end of the air exhaust
line to catch fluid in case a diaphragm ruptures.
If the diaphragm ruptures, the fluid being pumped
will exhaust with the air.
T
Container for remote air exhaust
U
Muffler
Installation
11