Repair; Disassemble The Fluid Section - Graco ChemSafe 515 Series Instructions - Parts Manual

Air-operated diaphragm pump
Hide thumbs Also See for ChemSafe 515 Series:
Table of Contents

Advertisement

Repair

Repair
Repair
Repair
NOTE: Before repairing the pump, follow the
NOTE:
NOTE:
Pressure Relief Procedure, page
Disassemble
Disassemble
Disassemble the
1. Carefully remove all cap plugs (37). Turn the
pump upside-down.
2. Use a 10 mm socket to remove the base plates
(12) and the inlet manifold (10).
3. Remove the o-ring seals (17), d-rings (21), and
check balls (22) from inlet side of each fluid cover
(6).
4. Inspect the inlet ball retainers (20). If necessary
to replace, use a hook to remove without
scratching the inner bore.
5. Turn over the pump and use a 10 mm socket to
remove the manifold retainer (11) and the outlet
manifold (8).
6. Inspect both manifolds' (8 & 10) wearable seats
(35 & 36), and replace if worn or damaged.
NOTE: Use a small hammer and PVC tool (44)
NOTE:
NOTE:
to tap new wearable seats (35 & 36) into the
manifolds (8 & 10).
18
Springer Pumps, LLC
Telford, PA 18969
14.
the Fluid
the
Fluid Section
Fluid
Section
Section
Tel: 866-777-6060 / Int'l: 215-949-2900
Fax: 866-777-6383 / Int'l: 215-721-1296
7. Remove the o-ring seal (17) from the outlet side
of each fluid cover (6).
8. Without scratching the inner bore, use a hook to
remove the two outlet ball retainers (20).
9. Remove the check balls (22), d-rings (21), and
wearable seats (19) from the outlet side of each
fluid cover (6).
334794B
shop.springerpumps.com
info@springerpumps.com

Advertisement

Table of Contents
loading

This manual is also suitable for:

Chemsafe 515 pt seriesChemsafe 515 uh seriesChemsafe 515Chemsafe 515 ptChemsafe 515 uh